Water research

Occurrence of typical PFAS in fluorochemical wastewater treatment plant and efficient removal by pilot-scale granular activated carbon adsorption.

Aimin Zhang, Wenjing Zong, Xiangzhe Jiang, Shanshan He, Tao Ou, Huiyi Zhang, Jiasen Huang, Lili Zhao,

State Key Laboratory of Regional Environment and Sustainability, School of Environment, Tsinghua University, Beijing, 100084, China; Sichuan Development Environmental Science and Technology Research Institute Co., Ltd, Chengdu, 610213, China; Sichuan Provincial Industrial Wastewater Pollution Control and Low Carbon Resource Utilization Engineering Technology Research Center, Chengdu, 610213, China. · State Key Laboratory of Regional Environment and Sustainability, School of Environment, Tsinghua University, Beijing, 100084, China.

Key points

From the paper's conclusion
  • These findings show that GAC is selective and effective for removing PFOA and its substitutes from fluorochemical wastewater, providing a basis for source reduction of PFAS emissions from fluorochemical industrial parks.

Abstract

Fluorochemical wastewater treatment plants (WWTP) are main direct-discharge sources of PFAS, but their occurrence and end-of-pipe removal remain unclear. This study investigated the typical PFAS occurrence in a centralized fluorochemical WWTP, and then their removal by pilot-scale granular activated carbon (GAC) adsorption. Eleven PFAS were detected in wastewater, and perfluoro-2,5-dimethyl-3,6-dioxaheptanoic acid (C7 HFPO-TA) was dominant with the concentrations of 822.5-1349.2 μg/L and contributions of 72.0%-83.3% to ΣPFAS, whereas PFOA accounted for only 0.9%-1.4%. The process-profile samples showed no consistent decrease in ΣPFAS or C7 HFPO-TA across the conventional treatment train. Longer-chain PFAS were relatively enriched in mixed sludge, although this enrichment did not coincide with lower aqueous concentrations in the sampled treatment profile. The end-of-pipe removal of PFAS by GAC adsorption was strongly compound-dependent. The lead-lag system effectively controlled C7 HFPO-TA and PFOA but provided limited sustained removal of short- and ultrashort-chain PFAS. During pilot operation, cumulative aqueous-phase mass reductions were 94.1% for C7 HFPO-TA and 99.5% for PFOA. Short-chain PFAS broke through early and showed apparent release consistent with competitive displacement, whereas TFA and PFPrA were minimally retained. The operating cost estimated using C7 HFPO-TA 10% breakthrough as the control endpoint was 0.26 $/m3 wastewater. These findings show that GAC is selective and effective for removing PFOA and its substitutes from fluorochemical wastewater, providing a basis for source reduction of PFAS emissions from fluorochemical industrial parks.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers