Sustainable coagulant optimization via inverse filtration control and ensemble learning in a full-scale drinking water plant.
Shuai Yang, Xin He, Chao Yin, Jianfeng Cai, Bin Xu, Naiyun Gao, Yulin Tang
College of Environmental Science & Engineering, Tongji University, Shanghai East Hospital, Key Laboratory of Water Supply, Water Saving and Ecological Governance in the Yangtze River Delta, Ministry of Water Resources, Shanghai, 200092, China. · Shanghai Qingpu Water Supply Co., Ltd, Shanghai, 201700, China.
Key points
From the paper's conclusion- A retrospective model simulation, based on 1,704 daily operational records (2021-2025) and evaluated over the continuous future block, estimated a potential mean coagulant dosage reduction of 10.1% at a sedimentation turbidity target of 1.03 NTU.
Abstract
Excessive reliance on conservative coagulant dosing to buffer raw water fluctuations in drinking water treatment plants (DWTPs) frequently leads to chemical redundancy and elevated carbon emissions. This study proposed a novel strategy shifting the primary turbidity control boundary downstream to the sand filter, termed Inverse Filtration Control (IFC), to optimize coagulant efficiency. This strategy leveraged the inherent particulate retention capacity across the treatment continuum and optimized the nonlinear coagulant demand. This research developed a cascaded Boosting-based generalized regression neural network (Boosting-GRNN) to reliably execute this strategy and effectively decouple global water quality trends from high-frequency fluctuations. Leakage-free chronological evaluation over the continuous future block yielded R2 values of 0.9462 and 0.9156 for coagulant dosage and sand filter effluent turbidity predictions, respectively. A retrospective model simulation, based on 1,704 daily operational records (2021-2025) and evaluated over the continuous future block, estimated a potential mean coagulant dosage reduction of 10.1% at a sedimentation turbidity target of 1.03 NTU. Under the historical annualization assumptions, this corresponds to approximately 271 t of PAC and 298 t of CO₂-eq per year. SHAP analysis further indicated distinct patterns of model feature reliance across the two predictive modules, providing a transparent basis for evaluating the digital twin framework. This study bridged the gap between isolated unit operations and coordinated inter-unit control, and offered a transparent, verifiable digital twin roadmap for sustainable and low-carbon water utility operations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine Learning-Based Prediction and Interpretation of Aluminum and Iron Coagulant Dosages in Drinking Water TreatmentSustainability · 2026
- AI-enabled CPS operational framework with daily-retrained model bank for chemical resource optimization in drinking-water treatment.Journal of environmental management · 2026
- A decision support system for coagulant dosage using explainable NSGA-II optimized stacking frameworkJournal of Water Process Engineering · 2026
- Forecasting the Removal of Chemical Contaminants of Emerging Concern in Activated Sludge Treatment—A Practical, Site-Calibrated Model Supporting Implementation of the EU Urban Wastewater Treatment Directive RecastWater · 2026
- HydroSphere: A Framework for Governed, Self-Healing Wastewater InfrastructurearXiv · 2026
- Granular Activated Carbon versus Ion Exchange: A Decision Space for Navigating Economic and Environmental Tradeoffs during Water Treatment Technology SelectionACS ES&T Engineering · 2026