Controlling 1,4-dioxane and disinfection byproducts during ozone/hydrogen peroxide-granular activated carbon drinking water treatment while maintaining ozone residuals for pathogen inactivation credit.
Yuhao Xian, Brian Yeung, Seth Sandoval-Skeet, Nazmiye Cemre Birben, Lutgarde Raskin, Rebecca Lahr, Yi-Hsueh Chuang, Aleksandra Szczuka
Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA. · Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA; Department of Chemical & Environmental Engineering, Yale University, New Haven, CT, USA.
Key points
From the paper's conclusion- We evaluated 1,4-dioxane removal, bromate control, and formation potential of 28 regulated and unregulated disinfection byproducts (DBPs) in pilot-scale O₃-granular activated carbon (GAC) and O₃/H₂O₂-GAC treatment trains while maintaining O₃ residuals.
Abstract
Declining water quality and the need to control multiple contaminants with existing infrastructure present challenges for drinking water treatment plants. Retrofitting existing ozonation systems (O₃) to ozone/hydrogen peroxide (O₃/H₂O₂) can accelerate hydroxyl radical (•OH) generation and potentially enhance contaminant removal, while lowering measurable O₃ residuals required for pathogen inactivation credit. We evaluated 1,4-dioxane removal, bromate control, and formation potential of 28 regulated and unregulated disinfection byproducts (DBPs) in pilot-scale O₃-granular activated carbon (GAC) and O₃/H₂O₂-GAC treatment trains while maintaining O₃ residuals. At the 1.7 mg/L O₃ dose needed to maintain ≥ 0.3 mg/L O₃ residual, 44.7 ± 1.9% of 10 μg/L 1,4-dioxane was removed, exceeding previously reported removal. Modeling results indicated that •OH formation during O₃ decay (20°C) at pH ∼8.0 and dissolved organic carbon ∼4 mg-C/L drove removal. H₂O₂ addition increased 1,4-dioxane removal by <14% and mitigated up to 56 ± 11% bromate, although mitigation was constrained by low H₂O₂/O₃ ratios required to maintain O₃ residual. O₃/H₂O₂ treatment did not improve DBP and chloramine-associated DBP formation control, but reduced chlorine-associated DBP formation by 9-20% while increasing calculated additive toxicity (CAT) by 16-41% due to elevated haloacetaldehyde and halonitromethane formation. Subsequent GAC treatment reduced DBP formation after chlorination by 4-17% and CAT by 20-47%. Thiol reactivity and CAT showed different trends, indicating the need for complementary toxicity assessments. These results highlight the challenge of simultaneously controlling chemical contaminants within the current pathogen crediting framework.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Fe3O4‑Coated Activated Carbon Catalyst for Drinking Water Disinfection and Toxic Disinfection Byproduct Control.ACS omega · 2026
- Control of Brominated and Iodinated DBPs within a Drinking Water Distribution System with Granular Activated Carbon and Biological FiltrationEnvironmental Science & Technology · 2026
- Linking Targeted GC–MS Disinfection Byproduct Analysis with Nontargeted LC–HRMS Characterization of Dissolved Organic Matter to Evaluate Drinking Water Treatment PerformanceACS ES&T Water · 2026
- Environmental impacts and economic assessment of a large-scale pilot plant for micropollutants removal: Granular activated carbon vs. coupled advanced oxidation process-granular activated carbon treatmentsJournal of environmental chemical engineering · 2025
- Assessment of a Daphnia–Biofilm Quaternary Water Treatment for Water Renaturalisation: Microbial and Chemical ChangesWater · 2026
- Bromate Formation and Control During Ozonation in Advanced Wastewater Purification for Potable Reuse.Water environment research : a research publication of the Water Environment Federation · 2026