Vision research

Low-dose atropine (0.01%) and visual discomfort: A clinic-based cohort linking pupil metrics, lighting context, and symptomatology in myopia control.

Labishetty Sai Charan, Vandana Mahaur, Himanshu Tripathi

Department of Optometry, NIMS College of Allied and Healthcare Sciences, Nims University Rajasthan, Jaipur, Rajasthan, 303121, India; Department of Optometry, University Institute of Allied Health Sciences, Chandigarh University, Mohali, Punjab, 140413, India. Electronic address: charansai184@gmail.com. · Department of Ophthalmology, National Institute of Medical Sciences and Research, Nims University, Jaipur, 303121, India.

Observational · n=120

Key points

From the paper's conclusion
  • These findings indicate that 0.01% atropine does not increase visual discomfort and may confer a modest protective effect modulated by spectral characteristics of ambient lighting.

Abstract

Low-dose atropine (0.01%) is widely used for pediatric myopia control, yet its effect on light-related visual discomfort under real-world lighting remains uncertain. We assembled a clinic-based observational cohort of 120 adolescents (12-18 years; myopia -3.00 to -6.00 D spherical equivalent) and compared 69 atropine users with 51 non-atropine controls. The primary outcome was a validated 0-10 visual discomfort composite score (Visual Discomfort Scale, VDS-10), administered under standardized ambient conditions (300 lx, 5000 K), with secondary measures including glare threshold (cd/m2; C-Quant, Oculus GmbH), pattern-glare score (Wilkins/Evans protocol), photopic and mesopic pupil diameters (PLR-200, NeurOptics), reading speed, and ambient lighting logged via wearable spectroradiometric sensors (Sekonic C-800). Multivariable ordinary least squares (OLS) models with HC3 robust standard errors and inverse probability of treatment weighting (IPTW) adjusted for age, sex, screen-time, pupil metrics, illuminance, and correlated color temperature (CCT). Unadjusted means showed lower discomfort with atropine (mean 3.56 vs 4.67; mean difference - 1.12). Adjusted OLS yielded a non-significant atropine coefficient (β = 0.82; 95% CI -2.23 to 3.87; p = 0.598), while IPTW indicated a significant reduction (β ≈ -1.00; 95% CI -1.51 to -0.49; p < 0.001). A significant Atropine×CCT interaction indicated greater discomfort attenuation at higher CCT among atropine users; Atropine×Illuminance was not significant. Secondary outcomes showed no group differences in glare threshold, pattern-glare, pupil diameters, or reading speed. These findings indicate that 0.01% atropine does not increase visual discomfort and may confer a modest protective effect modulated by spectral characteristics of ambient lighting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers