Influence of measurement method, measurement height, and sampling location on carbon dioxide and ammonia concentration in a conventional piglet nursery.
Thies J Nicolaisen, Nina Volkmann, Lena Brügge, Rolf Nathaus, Nicole Kemper, Jochen Schulz
Institute for Animal Hygiene, Animal Welfare and Farm Animal Behaviour, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany. · vetxperts Reken, Lindenweg 8, 48734 Reken, Germany.
Key points
From the paper's conclusion- Therefore, measurements should be conducted at multiple locations within a compartment to capture spatial variability and to determine the most appropriate position for stationary sensors.
Abstract
Low air quality and the presence of harmful gases such as ammonia can have detrimental effects on the health and welfare of pigs. Excessive concentrations of these gases are particularly common in negative pressure ventilated barns found in conventional husbandry systems. There are various devices and guidelines available for measuring harmful gases in such environments. In this study, ammonia and carbon dioxide were measured using three different devices. Measurements were taken across four production cycles in six pens at two different heights (0.6 m, within test pens; 1.5 m, representing human working height). The measurement results for ammonia and carbon dioxide obtained with the three different methods differed significantly from one another. Comparison of the two measurement heights revealed no significant difference for ammonia. However, measurement height had a significant effect on carbon dioxide concentrations. Furthermore, the location of the sampling points (test pens) within the compartment significantly influenced the measured concentrations of both ammonia and carbon dioxide, indicating spatial variability. When assessing air quality in a barn, it is advisable to use two different measurement systems for ammonia and carbon dioxide to ensure reliable results. Measuring ammonia does not necessarily have to be performed at animal height, as its vertical distribution was found to be uniform within the compartment. However, the location of the sampling points significantly influenced both ammonia and carbon dioxide concentrations. Therefore, measurements should be conducted at multiple locations within a compartment to capture spatial variability and to determine the most appropriate position for stationary sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Field Verification and Multi-Site Deployment of a Multi-Sensor Node for Continuous Environmental Monitoring in Commercial Beef Cattle Facilities.Animals : an open access journal from MDPI · 2026
- Comparative evaluation of daytime indoor air quality parameters in four sheep housing systems under cold climate conditions: an exploratory case study.Environmental science and pollution research international · 2026
- Assessing the role of ventilation and indoor air quality in SARS-CoV-2 transmission risk in Belgian nursing homes: the AIR-CO study.Archives of public health = Archives belges de sante publique · 2026
- Evaluation of 4 carbon dioxide mass balance models for estimating the ventilation rate of naturally ventilated dairy barns.Journal of dairy science · 2026
- Effects of temperature and manure urea concentration on gaseous ammonia production rates in an in vitro systemThe Journal of Agricultural Science · 2026
- Atmospheric CO 2 and CH 4 measurements at Schauinsland station, Germany: a comparative study of diurnal and seasonal variations at 12 and 35 m intake heightAtmospheric Measurement Techniques · 2026