Effect of dissolved gas on sonochemical H2O2 generation, NO2-/NO3- formation, and ibuprofen degradation in a 300 kHz sonoreactor.
Jongbok Choi, Yeji Lee, Pengpeng Qiu, Muthupandian Ashokkumar, Younggyu Son
School of Chemistry, Faculty of Science, University of Melbourne, VIC 3010, Australia. · Department of Environmental Engineering, Kumoh National Institute of Technology, Gumi 39177, South Korea.
Key points
From the paper's conclusion- This study investigated the effect of dissolved gas on sonochemical oxidant generation and aqueous organic pollutant degradation in a 300 kHz ultrasonic system using twelve Ar/O2, O2/N2, and N2/Ar gas mixtures·H2O2 generation, NO2-+NO3- formation, sonochemiluminescence (SCL) imaging, and ibuprofen (IBP) degradation were measured to evaluate cavitation-induced radical activity under different gas c
Abstract
This study investigated the effect of dissolved gas on sonochemical oxidant generation and aqueous organic pollutant degradation in a 300 kHz ultrasonic system using twelve Ar/O2, O2/N2, and N2/Ar gas mixtures·H2O2 generation, NO2-+NO3- formation, sonochemiluminescence (SCL) imaging, and ibuprofen (IBP) degradation were measured to evaluate cavitation-induced radical activity under different gas conditions. Ar:O2 (75:25) maximized H2O2 production (54.1 μM after 60 min) and SCL intensity, reflecting the combined effect of the high specific heat ratio of Ar and the H-radical-scavenging role of O2, whereas O2:N2 (25:75) yielded the highest NO2-+NO3- concentration (9.00 μM). Despite a 23.6-fold variation in the H2O2 generation rate constant across gas conditions, the IBP degradation rate constant varied only 2.3-fold, revealing a fundamental decoupling between conventional dosimetric indicators and actual pollutant removal efficiency. This weak sensitivity is attributed primarily to the low substrate concentration used, with the ionization state of IBP and its interfacial behavior playing a secondary role. These findings demonstrate that no single dosimetric indicator adequately represents sonochemical degradation performance for ionizable aqueous organic pollutants, and that combined use of H2O2, NO2-/NO3-, and direct target-compound degradation measurements is necessary for comprehensive evaluation of sonochemical oxidation systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sonochemical degradation of CCl4 in an Ar-H2 dissolved aqueous solution.Ultrasonics sonochemistry · 2026
- Energy-normalized ascorbic acid sono-dosimetry for assessing cavitation-derived oxidative activity.Ultrasonics sonochemistry · 2026
- Cavitation-regime-controlled synergy in high-frequency sonophotocatalysis.Ultrasonics sonochemistry · 2026
- A parsimonious Langmuir-Freundlich loading-response framework for sonochemical degradation of nonvolatile organic contaminants: Model comparison, validation, and identifiability.Ultrasonics sonochemistry · 2026
- Kinetic analysis with a Langmuir-type mechanism for sonochemical degradation of ionic surfactants.Ultrasonics sonochemistry · 2026
- Interaction between number of formed bubbles, reaction rate and flow velocity of acoustic streaming in the initiation period of power-induced quenchingUltrasonics Sonochemistry · 2026