Quantitative Ultrasound-Based Machine Learning Versus the FAST Score for Identifying At-Risk MASH: A Retrospective Single-Center Study.
Yudai Fujiwara, Hidekatsu Kuroda, Tamami Abe, Kaname Inarimori, Ippeki Nakaya, Asami Ito, Takuya Watanabe, Hiroki Sato,
Division of Gastroenterology and Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan. Electronic address: yudfuji@gmail.com. · Division of Gastroenterology and Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan.
Key points
From the paper's conclusion- ML models integrating QUS parameters and AST outperformed the FAST score in identifying at-risk MASH in this single-center cohort, with Ensemble showing the best discrimination.
Abstract
OBJECTIVE: Since pharmacological therapies were approved for noncirrhotic adults with at-risk metabolic dysfunction-associated steatohepatitis (MASH), identifying this population noninvasively has become urgent. We therefore developed machine learning (ML) models using quantitative ultrasound (QUS) parameters and serum AST, and compared them with the FibroScan-AST (FAST) score. METHODS: This retrospective study included 418 patients with biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD), 138 with at-risk MASH. Five ML models were developed using four QUS parameters obtained from a general-purpose ultrasound system (LOGIQ E10, GE HealthCare) (ultrasound-guided attenuation parameter, integrated backscatter coefficient [IBSC], signal-to-noise ratio, and two-dimensional shear wave elastography), together with serum AST. Performance was assessed by nested cross-validation (CV) and compared with the FAST score using the DeLong test and Brier scores. A sensitivity analysis excluded patients with F4 fibrosis. SHapley Additive exPlanations (SHAP) quantified feature contributions. RESULTS: All five ML models outperformed the FAST score (cross-validated area under the receiver operating characteristic curve [CV-AUROC], 0.739 [95% CI: 0.690-0.789]; p < 0.05). Ensemble achieved the highest CV-AUROC (0.834 [0.795-0.873]), and the lowest Brier score (0.152). Results were similar after excluding F4 fibrosis (Ensemble, 0.827; FAST, 0.729; p = 0.001). SHAP identified IBSC as the most influential followed by two-dimensional shear wave elastography and AST. CONCLUSION: ML models integrating QUS parameters and AST outperformed the FAST score in identifying at-risk MASH in this single-center cohort, with Ensemble showing the best discrimination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LAD-NASH score using multiparametric ultrasound for identification of at-risk MASH: head-to-head comparison with the FAST score.Ultrasonography (Seoul, Korea) · 2026
- Noninvasive Detection of MASH and Fibrotic Burden Using Ultrasound-Derived LIID and LSM in MASLD: A Multicenter Study.Journal of gastroenterology and hepatology · 2026
- A multicohort proteomics-based machine learning score (MASHPredict) for noninvasive diagnosis and long-term prognostication of metabolic dysfunction-associated steatohepatitis.Frontiers in immunology · 2026
- Development of a machine learning model to identify individuals with VCTE-derived at-risk MASH in a Spanish Mediterranean region.Frontiers in digital health · 2026
- Assessment of Non-Invasive Tests for MASLD, MASH and At-Risk MASH in a Multicentre Prospective Real-World Study.Diabetes, obesity & metabolism · 2026
- Integrating Plain 2D Ultrasound and Clinical Data for Identification of At-Risk MASH: A Multicenter Proof of Concept Study.Journal of gastroenterology and hepatology · 2026