Ultrasound in medicine & biology

Intra- and Inter-Observer Reliability of Quantitative Brain Perfusion Metrics From Contrast-Enhanced Ultrasound in Neonatal Brain.

Tiina Laurikainen, Aapo Sirén, Hendrik Rummel, Riitta Parkkola, Lotta Westerholm, Anita Arola, Liisa Lehtonen, Vilhelmiina Parikka,

Department of Radiology, University of Turku and Turku University Hospital, Turku, Finland. Electronic address: tiina.laurikainen@varha.fi. · Department of Radiology, University of Turku and Turku University Hospital, Turku, Finland.

Key points

From the paper's conclusion
  • In this exploratory study, quantitative brain perfusion CEUS metrics analyzed using commercially available software were most reliable for thalamic measures among three readers with varying experience. These preliminary results support further evaluation of thalamic CEUS perfusion metrics in larger cohorts using standardized acquisition and analysis protocols.

Abstract

OBJECTIVE: Contrast-enhanced ultrasound (CEUS) is a promising, easily available bedside method for evaluating perfusion in neonates. The reliability of brain perfusion metrics analysis is currently unknown. This study aimed to determine the intra- and inter-observer reliability of variables derived from quantitatively analyzed time-intensity curves in neonatal brain CEUS data. METHODS: Thirteen CEUS studies of the brain were performed through the anterior fontanelle in 10 neonates on days 0-3. Two-min cine clips were recorded after intravenous contrast agent administration and analyzed with commercially available third-party software. Three raters with varying levels of expertise determined four regions of interest on the images: the bilateral thalami and two reference regions. The reference areas consisted of a frontoparietal focal area for the first and a whole-brain coronal for the second, excluding central gray nuclei. Quantitative perfusion metrics were analyzed for these regions. For intra-observer reliability, each rater re-analyzed a subset of ten examinations, after an interval of at least 2 mo. Intra- and inter-rater reliability statistics were calculated. RESULTS: In the bilateral thalamus, intra-observer reliability was excellent for most parameters, and inter-observer reliability was good to moderate. Results across the two reference areas were variable, showing at best moderate correlations with the second, larger reference area. CONCLUSION: In this exploratory study, quantitative brain perfusion CEUS metrics analyzed using commercially available software were most reliable for thalamic measures among three readers with varying experience. These preliminary results support further evaluation of thalamic CEUS perfusion metrics in larger cohorts using standardized acquisition and analysis protocols.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Intra- and Inter-Observer Reliability of Quantitative Brain Perfusion Metrics From Contrast-Enhanced Ultrasound in Neonatal Brain — Science Skim