Pilot study of a low-attenuation anechoic gastrointestinal contrast filling agent for enhancing transabdominal ultrasound examination of the pancreas.

Di Zhang, Guan-Yu Wang, Chang-Tian Li, Tai-Mei Qu, Xue-Ting Bai, Yi Zhao, Han-Jing Gao, Shi-En Xu,

Institute of Acoustics, Chinese Academy of Sciences, Beijing, China. · Faculty of Hepato-Biliary-Pancreatic Surgery, The First Medical Center of Chinese PLA General Hospital, Beijing, China; School of Medicine, Nankai University, Tianjin, China.

Key points

From the paper's conclusion
  • LAA-GFCA demonstrates a favorable safety profile in pre-clinical and pilot clinical studies, with promising potential to enhance pancreatic transabdominal ultrasound. Future larger-scale studies are warranted to confirm its diagnostic utility.

Abstract

BACKGROUND: Transabdominal ultrasound is constrained by gastric gas and collapsed folds when evaluating the pancreas. This study developed a low-attenuation anechoic gastrointestinal filling contrast agent (LAA-GFCA) composed of food-grade ingredients and performed a safety evaluation. METHODS: Acoustic characterization of LAA-GFCA was performed using the water-immersion insertion substitute method, with phantom experiments designed to evaluate imaging performance. Pre-clinical safety studies were conducted in rabbits, followed by a clinical pilot study in healthy volunteers to assess safety and the optimal imaging window. RESULTS: Acoustic characterization of LAA-GFCA showed that its speed of sound (1541.2 m/s at 34.9°C) matched human soft tissue, with an ultra-low-attenuation coefficient slope (0.024 dB/(cm·MHz)) at the test frequency of 3.5 MHz. Phantom experiments demonstrated enhanced visualization of cyst-like and gray-scale lesions versus cereal-based echoic gastrointestinal filling contrast agent. Pre-clinical studies in eight rabbits confirmed no acute toxicity. Clinical pilot trials in 10 healthy volunteers verified safety and identified the optimal imaging window as 6-15 min after oral administration, enabling clear visualization of the entire pancreas. CONCLUSION: LAA-GFCA demonstrates a favorable safety profile in pre-clinical and pilot clinical studies, with promising potential to enhance pancreatic transabdominal ultrasound. Future larger-scale studies are warranted to confirm its diagnostic utility.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Pilot study of a low-attenuation anechoic gastrointestinal contrast filling agent for enhancing transabdominal ultrasound examination of the pancreas — Science Skim