Quantification of microbubble-induced streaming across ultrasound frequencies using particle image velocimetry.
Reza Rasouli, Brad Hartl, Soren D Konecky
Openwater, San Francisco, CA, United States.
Key points
From the paper's conclusion- These findings underscore that acoustic frequency plays a substantial role in intensity of microbubble-induced streaming, with low-frequency excitation in the 150-300 kHz range producing markedly more efficient streaming and associated shear.
Abstract
Functional microbubbles are widely used in therapeutic ultrasound for drug delivery, blood-brain barrier opening, clot lysis, and other biomedical interventions. Their therapeutic effects arise largely from acoustic microstreaming, which generates localized shear stresses and enhances transport around oscillating bubbles. Despite the central role of microstreaming, its dependence on ultrasound excitation conditions is not well defined. Existing studies use diverse and often incomparable frequencies, pressures, and duty cycles, leaving a gap in systematic understanding of how these parameters govern the streaming velocity and shear fields produced by functional microbubbles under physiologically relevant conditions. In this study, we employ particle image velocimetry (PIV) in a popliteal-vein lab-on-chip model to directly quantify the microstreaming velocity and shear-rate fields generated by microbubbles across a wide range of ultrasound conditions including frequency, duty cycle, and acoustic pressure. Measurements at 150 kHz, 300 kHz, 500 kHz, and 1 MHz reveal a pronounced frequency dependence. Counterintuitively, the strongest microstreaming is observed at 150 kHz, with progressively weaker streaming at 300 and 500 kHz, and the weakest flows at 1 MHz. This trend contrasts with the common assumption that microbubble oscillations peak near their ∼ 1MHz resonance frequency. Duty cycle further modulated the response: 10 % duty cycle generated the weakest fields, whereas 100 % duty cycle produced maximal streaming. Pressure-scaling was strongly frequency-dependent. At 150 kHz, raising the driving pressure from 100 to 300 kPa increased the mean streaming velocity by up to fourfold, whereas at 1 MHz the same pressure increase produced essentially no change in velocity. These findings underscore that acoustic frequency plays a substantial role in intensity of microbubble-induced streaming, with low-frequency excitation in the 150-300 kHz range producing markedly more efficient streaming and associated shear. Operating within this low-frequency window identifies therapeutically relevant velocity and shear levels, but choice of pressure must balance streaming efficacy against the narrow pressure range over which cavitation can be maintained at sub-MHz frequencies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Shape Oscillation and 3-D Microstreaming Profile of a Phospholipid-Coated Microbubble Attached to a Wall.IEEE transactions on ultrasonics · 2026
- Sub-wavelength scale randomly frozen microbubble during short-pulsed-ultrasound-driven microbubble cluster dynamics in microfluidic channelUltrasonics Sonochemistry · 2026
- Research on the Design of Micromixer Based on Acoustic Streaming-Driven Sharp-Edge StructuresSensors · 2025
- Tuning endothelial barrier permeability with ultrasound: a pulse-length-dependent interplay between bubble dynamics and cellular bioeffectsUltrasonics Sonochemistry · 2026
- Ultrasound-driven electronically programmable microbubblesScience Advances · 2026
- Ultrasound contrast microbubble scattering in viscoelastic mediaFrontiers in Acoustics · 2026