Mean-shift-based spatiotemporal microbubble signal enhancement for high-concentration ultrasound localization microscopy.
Liyang Wu, Yuexiang He, Yue Zhang, Siping Chen, Haoming Lin, Xin Chen
National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518071, Guangdong, China. Electronic address: 2550241008@mails.szu.edu.cn. · National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518071, Guangdong, China. Electronic address: 2310247014@email.szu.edu.cn.
Key points
From the paper's conclusion- We propose MS-ULM, a mean-shift-based pre-localization enhancement framework that improves the local peak representation of clutter-filtered microbubble signals so that conventional localization methods can recover more useful microbubble events for limited-frame reconstruction.
Abstract
Ultrasound localization microscopy (ULM) achieves super-resolution microvascular imaging by localizing and tracking intravascular microbubbles. Under high-concentration conditions, echoes from adjacent microbubbles can overlap spatially, causing responses to broaden or merge and weakening the local peak structures required for conventional localization. Consequently, microbubble information already present in each frame may become difficult to detect and localize. We propose MS-ULM, a mean-shift-based pre-localization enhancement framework that improves the local peak representation of clutter-filtered microbubble signals so that conventional localization methods can recover more useful microbubble events for limited-frame reconstruction. MS-ULM uses mean-shift spatial aggregation to exploit local spatial-intensity distributions and concentrate spatially diffuse, overlapping, or low-saliency responses toward dominant local intensity peaks. Rather than explicitly separating every overlapping microbubble, it re-expresses existing microbubble information to better match the local peak structure required by conventional localization. Doppler-frequency-polarity-based directional separation and lag-1 temporal coherence processing are further incorporated to reduce directional mixing and suppress temporally incoherent fluctuations and isolated pseudo-peaks. The enhanced signals are processed using the same radial-symmetry localization, tracking, filtering, and reconstruction procedures as the baseline pipeline. Simulations showed improved recall and F1-score and greater retention of true-positive localizations in valid trajectories. In vivo rat brain experiments showed more valid trajectories, improved limited-frame vascular filling, and a Fourier ring correlation (FRC) resolution of 42.3±0.4μm; representative rat kidney experiments further supported cross-organ applicability. These results show that improving the pre-localization representation of existing microbubble information enables more complete high-concentration, limited-frame ULM reconstruction without modifying downstream algorithms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temporal Waveform Reconstruction Algorithm for Fast Super-resolution Ultrasound Imaging.BME frontiers · 2026
- Multi‑stage singular value decomposition for ultrafast ultrasound imaging of microbubbles.Ultrasonics · 2026
- C2-ULM: Data-Efficient ultrasound localization microscopy via coherent prior MAP beamforming for Sparse, compressed receive acquisition.Ultrasonics · 2026
- Physics-Based Differentiable Beamforming for Deep Learning-Based Contrast Enhanced Ultrasound Super-Resolution ImagingarXiv · 2026
- Microbubble Track-Based Functional Ultrasound Localization Microscopy in Awake MiceIEEE Transactions on Medical Imaging · 2026
- Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants.ArXiv · 2026