Ultrasonic interference analysis and elimination for LED-based photoacoustic imaging systems.
Enxiang Shen, Qian Wang, Yuxin Wang, Zhendong Yao, Xiao Yin, Kanglian Zhao, Jie Yuan
School of Electronic Science and Engineering, Nanjing University, China. Electronic address: shenenxiang@smail.nju.edu.cn. · School of Electronic Science and Engineering, Nanjing University, China. Electronic address: 201180015@smail.nju.edu.cn.
Key points
From the paper's conclusion- This study provides an in-depth analysis of the noise issues in LED-based PAI systems, which might contribute to enhanced image quality and the development of low-cost photoacoustic systems, thereby facilitating the broader clinical application of LED-based photoacoustic imaging.
Abstract
Photoacoustic imaging (PAI) enables visualization of optical absorption contrast through ultrasonic detection, and light emitting diode (LED) based PAI systems have attracted attention due to their high repetition rates, portability, and cost-effectiveness. However, these systems typically require high driving currents and rapid switching speeds to activate the LEDs, which generates significant electromagnetic interference (EMI). In this study, we identified that this EMI induces currents within the ultrasound probe circuitry, driving the probe to passively emit ultrasonic waves and resulting in ultrasonic noise. To address this issue, we analyzed the amplitude spectrum of the EMI signals and discovered that modulating the LED pulse width shifts its spectral nulls. A pulse width adjustment algorithm was proposed based on the ultrasound probe bandwidth. By aligning the spectral nulls with the center frequency of the probe, EMI coupling is minimized, thereby reducing ultrasonic noise. Additionally, we propose a residual reconstruction algorithm based on an optical shutter. Since the optical shutter modulates the generation of photoacoustic signals while leaving the ultrasonic noise unaffected, computing the residual between images reconstructed in the open-shutter and closed-shutter states allows for the elimination of ultrasonic noise. Validated on phantoms and in vivo human vessels, pulse width adjustment improved the signal-to-noise ratio by 3.4 dB, while residual reconstruction yielded an enhancement of 13.3 dB. This study provides an in-depth analysis of the noise issues in LED-based PAI systems, which might contribute to enhanced image quality and the development of low-cost photoacoustic systems, thereby facilitating the broader clinical application of LED-based photoacoustic imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Defect detection using a laser diffuse ultrasonic phased array via selective transmitted wavesApplied Physics Letters · 2026
- Feasibility of an ultrafast and low-cost image sensor based on single-pulse photomechanical with minimal electronics electromagnetic detection (SPEED).Physics in medicine and biology · 2026
- Entropy weighted TOPSIS optimized interferometric synthetic aperture focusing technique (InSAFT) for laser-ultrasonic defect imaging.Ultrasonics · 2026
- Low-Cost Photoacoustic Imaging System for Vascular Occlusion Detection in Polymer Phantoms.Journal of lasers in medical sciences · 2026
- Near-infrared-II pulsed laser diode array for spectral photoacoustic imaging of deep tissue oxygenationBiomedical Optics Express · 2025
- Uncovering hidden structural and mechanical contrast via spectral photoacoustic imaging.Optics express · 2026