Thickness determination from EDXS maps acquired in a transmission electron microscope and its application for shape reconstruction of nanoparticles.
Radian Popescu, Dagmar Gerthsen, Simon Hettler, Martin Peterlechner, Erich Müller, Damien Hudry, Yolita Maria Eggeler
Laboratory for Electron Microscopy (LEM), Karlsruhe Institute of Technology (KIT), Engesserstr. 7, 76131 Karlsruhe, Germany. Electronic address: radian.popescu@kit.edu. · Laboratory for Electron Microscopy (LEM), Karlsruhe Institute of Technology (KIT), Engesserstr. 7, 76131 Karlsruhe, Germany.
Key points
From the paper's conclusion- This paper describes a method that can be applied for the three-dimensional (3D) reconstruction of nanoparticles (NPs) with convex shapes performed using a single 2D energy dispersive X-ray spectroscopy (EDXS) map recorded without any tilt in a transmission electron microscope.
Abstract
This paper describes a method that can be applied for the three-dimensional (3D) reconstruction of nanoparticles (NPs) with convex shapes performed using a single 2D energy dispersive X-ray spectroscopy (EDXS) map recorded without any tilt in a transmission electron microscope. Data analysis is based on measured characteristic X-ray intensities of chemical elements chosen for the reconstruction that are transformed in their corresponding path lengths by using dedicated calibration factors. The method requires at least one measured calibration factor from which theoretical calibration factors can be calculated. By applying theoretical calibration factors, the method bears the potential to be a viable alternative to classical electron tomography. As advantages, this method can describe the shape of particles and their constituents located within agglomerates, when the substrate contaminates and when particle components contain elements with close atomic numbers. Moreover, it is not affected by missing wedge artifacts and does not require a tomography sample holder and dedicated software. Within this method, the 3D shape is symmetrically reconstructed along the electron-beam direction z from the NP center, which seems to restrict its applicability. However, many NPs synthesized under equilibrium conditions have convex, z-symmetrical shapes that can be reliably deduced from their 2D-projected shape on scanning TEM images. Even without assuming z-symmetrical shapes, the thickness in z-direction can always be evaluated. The method was applied to determine the 3D shape of a prismatic CeO2-CaF2 core-shell NP and an ellipsoidal Au35Co65 core-shell NP demonstrating its capability to deal with NPs having different morphologies and chemical compositions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A 4D-STEM Tomographic Framework Assisted by Object Tracking for Nanoparticle Structure Determination.Small methods · 2026
- The Hidden Cost of Two-Dimensional TEM Reconstruction of Magnetic Nanoparticle MorphologyarXiv · 2026
- Gaussian Splatoms: Direct Atomic Structure Identification in Electron TomographyarXiv · 2026
- Optimization-Based Thickness Estimation and Depth-Resolved FIB-Induced Damage Characterization via Multislice Electron PtychographyarXiv · 2026
- Imaging thick objects with deep-subangstrom resolution and deep-subpicometer precisionScience Advances · 2026
- 3D Reconstruction of Nanoparticle Distribution in Tumor Spheroids With Volume Electron MicroscopySmall · 2026