Talanta

A proposed binder-gated transduction model in molecularly imprinted carbon paste electrodes for reagentless vancomycin monitoring in biological matrices.

Aaryashree, Aoi Hirata

Innovative Global Program, College of Engineering, Shibaura Institute of Technology, Toyosu, Koto-city, Tokyo, 135-8548, Japan. Electronic address: aarya@sic.shibaura-it.ac.jp. · Department of Applied Chemistry, Graduate School of Science and Engineering, Shibaura Institute of Technology, Toyosu, Koto-city, Tokyo, 135-8548, Japan.

Key points

From the paper's conclusion
  • Here, we report a matrix-dependent conditioning phenomenon in MIP-CP electrodes deposited on a commercial screen-printed electrode platform.

Abstract

Vancomycin (VCM) is a first-line antibiotic for methicillin-resistant Staphylococcus aureus (MRSA) infections requiring strict therapeutic drug monitoring (TDM) due to its narrow therapeutic window. Electrochemical sensors based on molecularly imprinted polymer-grafted carbon paste (MIP-CP) offer a promising reagentless approach for rapid VCM detection, but their behavior in complex biological matrices remains poorly understood. Here, we report a matrix-dependent conditioning phenomenon in MIP-CP electrodes deposited on a commercial screen-printed electrode platform. MIP-CP sensors responded immediately and stably in phosphate-buffered saline (PBS) from the first measurement. In complex biological matrices, however, a storage period of approximately one week was required before a clean VCM response was obtained. As a working model, it is proposed that paste preparation and deposition mechanically disturb the silicone oil binder, transiently limiting access to the MIP cavities. Gradual surface stabilization then restores access, whereas slow bulk oil migration reduces sensitivity over longer periods, resulting in a usable window of approximately one to four weeks. After 30 days of storage, the sensor exhibited a linear response from 0 to 40 μg/mL in human serum (sensitivity 0.0036 μA mm-2 per μg mL-1, 95% confidence interval 0.0022 to 0.0050, R2 = 0.96, n = 3 independent electrodes). In PBS, the response toward the structural analog teicoplanin was markedly lower, and 0.5 μg/mL acetaminophen altered the response by less than 7%. These findings provide practical guidance for the pre-use preparation of disposable MIP-based TDM sensors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers