Talanta

Machine learning-empowered dual-sensor array for pH-adaptive electrochemical detection of carbendazim residues.

Li Zhang, Lei Zhang, Guanyu Chen, Haiyi Chen, Hao Qin, Taige Li, Tianhao Liu, Jun Luo

State Key Laboratory of Water Pollution Control and Green Resource Recycling, School of Environment, Nanjing University, Nanjing, 210023, PR China. · State Key Laboratory of Water Pollution Control and Green Resource Recycling, School of Environment, Nanjing University, Nanjing, 210023, PR China. Electronic address: esluojun@nju.edu.cn.

Computational

Key points

From the paper's conclusion
  • The sensor enabled accurate CBZ quantification without pH pre-adjustment, achieving recoveries of 78.00-108.50% in spiked real water samples and 80.33-126.00% on food surfaces, significantly outperforming linear calibration.

Abstract

Carbendazim (CBZ) is a widely used benzimidazole fungicide, but its residues persist in environmental water and on food surfaces, posing health risks. Electrochemical detection is attractive for in situ analysis. However, pH fluctuations in real samples significantly alter the dissociation and electrochemical activity of CBZ, compromising accuracy. Here, a dual-function sensor array was developed by integrating a screen-printed carbon electrode modified with an MXene@AgNSs/carbon nanotubes/electropolymerized l-cysteine composite (SPCE/MXene@AgNSs/CNT/L-Cys) for CBZ detection and a polyaniline (PANI) electrode for in situ pH monitoring. The composite facilitated the electrochemical response toward CBZ, while the electropolymerized L-Cys layer provided functional sites for analyte interactions. Using in situ pH and differential pulse voltammetry peak current as inputs, four machine learning regression models (GBDT, XGBoost, SVM, RF) were compared. GBDT achieved the best predictive performance (R2 = 0.982, RMSE = 1.44 μg mL-1, MAE = 0.99 μg mL-1) on the test set. SHAP analysis revealed that pH markedly modulated the concentration-current sensitivity outside the range of pH 6.0-7.5, causing pronounced nonlinearity, whereas diffusion-controlled behavior dominated within this window, and the model adaptively learned these boundaries. The sensor enabled accurate CBZ quantification without pH pre-adjustment, achieving recoveries of 78.00-108.50% in spiked real water samples and 80.33-126.00% on food surfaces, significantly outperforming linear calibration. This work provides a novel strategy for rapid, in situ pesticide detection under pH fluctuation by coupling interpretable machine learning with electrochemical sensor arrays, offering a promising pathway toward intelligent electrochemical sensing in complex real-world environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers