Talanta

Dual-readout cross-check ratiometric fluorescence strategy for quantitative and visual detection of alkaline phosphatase in foodstuffs.

Qian Yang, Yixuan Wu, Yan Yang, Jiadong Chen, Li Zhang, Jaebum Choo, Lingxin Chen

Institute for Advanced Study, Shaoxing University, Shaoxing, 312000, China. · Shandong Key Laboratory of Coastal Zone Environmental Processes and Ecological Security, Shandong Engineering Research Center for Coastal Zone Ecological & Environmental Monitoring Technologies and Equipment, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China.

Key points

From the paper's conclusion
  • To address this, we developed a dual-readout cross-check ratiometric fluorescence strategy based on two detection routes.

Abstract

Fluorescence detection suffers from poor visual discernibility, and ratiometric fluorescence methods have effectively mitigated this issue. However, accuracy remains affected by uncontrollable signal interferences. To address this, we developed a dual-readout cross-check ratiometric fluorescence strategy based on two detection routes. The first route comprised MnO2 nanosheets, thiamine, Alexa Fluor 488 and gold nanoclusters (AuNCs), providing three fluorescence channels (blue, green, and red) and enabling a blue-cyan-green-yellow-green visualization pathway for alkaline phosphatase (ALP) detection, an essential enzyme for foodstuff quality. Another route, MnO2-thiamine-AuNCs, offered two-channel (blue and red) detection with a blue-purple-purple-red color transition. These dual routes provided two ratiometric values and distinct color changes, enabling cross-checking that provides additional consistency information. Under optimized conditions, the assay showed a linear range of 0.1-100 mU/mL with a coefficient of determination (r2) of 0.998. The limits of detection (LODs) were 0.05 and 0.06 mU/mL for the two- and three-channel modes, respectively. The assay was successfully applied to real samples, providing results consistent with those from commercial assay kits and recoveries of 101.47%-107.43% with RSDs below 8% for spiked pasteurized milk. This multi-channel assay possesses great potential for reliable and visual quantification of analytes in complex matrices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Dual-readout cross-check ratiometric fluorescence strategy for quantitative and visual detection of alkaline phosphatase in foodstuffs — Science Skim