Talanta

Comprehensive graphical insights into mixed-mode chromatographic interactions by tailoring stationary-phase chemistries with kosmotropic and chaotropic ions.

Siddharth Jaya Sajeevan J, Alison G Blanton, Daniel W Armstrong

Department of Chemistry and Biochemistry, University of Texas at Arlington, 76019, USA. · Department of Chemistry and Biochemistry, University of Texas at Arlington, 76019, USA. Electronic address: sec4dwa@uta.edu.

Key points

From the paper's conclusion
  • The results showed that changing the mobile-phase additive, while maintaining all other chromatographic conditions, provided readily accessible selectivity.

Abstract

Mixed-mode/hydrophilic interaction liquid chromatography (HILIC) provides multiple retention mechanisms that can be adjusted to alter chromatographic selectivity. However, the influence of mobile-phase additives on these interactions across different stationary-phase chemistries remains insufficiently understood. In this study, the effects of kosmotropic and chaotropic salt ions were systematically evaluated on eight stationary phases using 14 probe analytes arranged into 12 analyte-pair comparisons representing eight categories of chromatographic interactions. Retention data obtained with five mobile-phase additives were analyzed using hierarchical clustering and principal component analysis to identify mobile-phase additive | stationary-phase combinations that produced the greatest differences in selectivity. The results showed that changing the mobile-phase additive, while maintaining all other chromatographic conditions, provided readily accessible selectivity. The magnitude and direction of mobile-phase additive effects differed among stationary phases, and the mobile-phase additive pair producing the greatest selectivity variance was not consistent across column chemistries. Electrostatic interactions and shape selectivity were the interactions most frequently affected by mobile-phase additive changes. The proposed data-analysis protocol was applied to the separation of biologically relevant dipeptides and stimulant drugs, demonstrating that salt-additive-dependent changes in selectivity can improve difficult separations. When alternative selectivity did not achieve baseline resolution, the chemometric approach of selective peak elimination enabled the extraction of underlying peak information. These findings provide a practical framework for selecting complementary chromatographic conditions, reducing redundant method development, solvent consumption, and analysis time, while supporting the design of multidimensional separations with minimized solvent-mismatch limitations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers