A paper-based molecularly imprinted electrochemical sensor for genistein: soybean screening in food products.
Patrícia Rebelo, Patrícia Ramos, Isabel Seguro, João G Pacheco, Maria Freitas, Henri P A Nouws, Cristina Delerue-Matos
REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Universidade Técnica do Porto, Rua Dr. António Bernardino de Almeida 431, Porto, 4249-015, Portugal. · REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Universidade Técnica do Porto, Rua Dr. António Bernardino de Almeida 431, Porto, 4249-015, Portugal. Electronic address: han@isep.ipp.pt.
Key points
From the paper's conclusion- Using differential pulse voltammetry, the MIP sensor revealed a linear response over the GEN concentration range of 0.1 - 2.5 μmol L-1, with a limit of detection of 0.03 μmol L-1, and good selectivity toward GEN and only slight interference of compounds that may coexist with GEN in food matrices.
Abstract
Soybean is one of the major regulated allergenic foods and is widely used in processed products. Because trace amounts may pose a serious risk to allergic consumers, uncertainty surrounding cross-contamination frequently results in precautionary allergen labeling, which may unnecessarily restrict food choices and underscores the need for rapid, sensitive, and cost-effective analytical tools for routine monitoring. This study presents an indirect approach for detecting soy-derived ingredients based on the determination of genistein (GEN), the predominant soybean isoflavone, using a paper-based electrochemical molecularly imprinted polymer (MIP) sensor. Conductive inks were used to print and modify the electrode system on a paper substrate. Through electropolymerization, the MIP recognition layer was prepared using 3-aminophenylboronic acid as the functional monomer and GEN as the template molecule. The different steps involved in the sensor's fabrication were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Using differential pulse voltammetry, the MIP sensor revealed a linear response over the GEN concentration range of 0.1 - 2.5 μmol L-1, with a limit of detection of 0.03 μmol L-1, and good selectivity toward GEN and only slight interference of compounds that may coexist with GEN in food matrices. This strategy was successfully used to detect GEN in a range of liquid and solid foods with accuracy confirmed by recovery values ranging from 88.6 to 105.2 %. The obtained results demonstrate the potential of the developed sensor as an environmentally friendly and cost-effective tool for routine monitoring of soy-derived ingredients, supporting allergen risk management and more informed allergen labeling decisions in the food industry.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid fluorimetric determination of glyphosate in beer and fruit juices using a chitosan-coated magnetic-fluorescent molecularly imprinted sensor.Food chemistry · 2026
- Molecularly imprinted polymer SiO2 nanostructures combined with anthocyanin from purple sweet potato peel for on-site colorimetric sensing of benzoic acid in milk.RSC advances · 2026
- Molecularly Imprinted Polymer-Based Sensors in Food Contaminants Analysis: Advances, Applications, and Future TrendsChemosensors · 2025
- Preparation of molecularly imprinted polymers based on core-shell magnetic mesoporous silica and application in the determination of estradiol.Journal of chromatography. A · 2026
- Advances in Molecularly Imprinted Electrochemical Platforms for Food Quality Control: Targeting Antioxidants, Sweeteners, Colorants, Contaminants and ToxicantsChemosensors · 2025
- Smart recognition of chemical contaminants in food: experimental and computational perspectives on MIP-based sensorsAnalytical Methods · 2026