Synergistic enhancement of laser-induced breakdown spectroscopy via Ag@Cu-MOFs/CMFP composite substrate for ultrasensitive detection of trace lead in water.
Bo Wang, Wenbao Jia, Wenjing Dong, Qing Shan, Yongsheng Ling, Zhichao Zhang
Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China. · Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, 215021, China.
Key points
From the paper's conclusion- Sensitive detection of lead (Pb) in water via laser-induced breakdown spectroscopy (LIBS) remains challenging due to plasma emission quenching by the aqueous matrix.
Abstract
Sensitive detection of lead (Pb) in water via laser-induced breakdown spectroscopy (LIBS) remains challenging due to plasma emission quenching by the aqueous matrix. To address this limitation, this study proposes a surface-enhanced LIBS (SE-LIBS) strategy coupled with analyte enrichment on a solid substrate. The substrate, denoted as Ag@Cu-MOFs/CMFP, was fabricated by growing a copper-based metal-organic framework (Cu-MOF) on carboxymethylated filter paper (CMFP), followed by deposition of silver nanoparticles (Ag NPs) through chemical reduction. The Cu-MOF layer selectively captures Pb2+ via ion exchange, delivering a high adsorption capacity of 59.7 mg g-1. This enrichment step effectively transfers dissolved Pb into a uniform solid matrix amenable to laser interrogation. Concurrently, Ag NPs enhance laser-matter coupling through localized surface plasmon resonance (LSPR). Plasma diagnostics revealed that the incorporation of Ag NPs increased the electron temperature by 2.1-fold, while the Pb I 405.8 nm emission intensity reached 4.3 times that of pristine filter paper. Under optimized experimental conditions, this method achieved a limit of detection (LOD) of 44.3 μg L-1 and a relative standard deviation (RSD) of 2.8%. The substrate also maintained excellent selectivity in the presence of competing cations. Recovery tests with river-water samples gave Pb recoveries of 97-104%. By synergistically combining MOF-mediated pre-concentration with AgNPs-assisted emission enhancement, this work offers a sensitive, selective, and field-compatible approach for Pb monitoring in aquatic environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- UiO-66 functionalized localized surface plasmon resonance fiber-optic sensor for ultra-trace lead ion detection.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Core-shell Ag/MOFs SERS platform for trace detection of organic dye contaminants.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Effects of substrate heating on surface-enhanced laser-induced breakdown spectroscopy using porous silicon with low-energy laser.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026
- Fabrication of Lead-based Metal-Organic Frameworks Using Recovered Lead for Solid-Phase Microextraction of p-Phenylenediamine Antioxidants.Journal of separation science · 2026
- Chromatic ion-receptor decorated UiO-66 MOF and porous hybrid polymer monolithic scaffolds as reusable solid-state opto-sensors for selective capturing of ultra-trace Pb2+ from aqueous samplesAdvanced Composites and Hybrid Materials · 2025
- SERS-based sensing of heavy metal ions and methylene blue using nanosecond laser ablated silver nanoparticles.RSC advances · 2026