Talanta

Synergistic enhancement of laser-induced breakdown spectroscopy via Ag@Cu-MOFs/CMFP composite substrate for ultrasensitive detection of trace lead in water.

Bo Wang, Wenbao Jia, Wenjing Dong, Qing Shan, Yongsheng Ling, Zhichao Zhang

Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China. · Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, 215021, China.

Key points

From the paper's conclusion
  • Sensitive detection of lead (Pb) in water via laser-induced breakdown spectroscopy (LIBS) remains challenging due to plasma emission quenching by the aqueous matrix.

Abstract

Sensitive detection of lead (Pb) in water via laser-induced breakdown spectroscopy (LIBS) remains challenging due to plasma emission quenching by the aqueous matrix. To address this limitation, this study proposes a surface-enhanced LIBS (SE-LIBS) strategy coupled with analyte enrichment on a solid substrate. The substrate, denoted as Ag@Cu-MOFs/CMFP, was fabricated by growing a copper-based metal-organic framework (Cu-MOF) on carboxymethylated filter paper (CMFP), followed by deposition of silver nanoparticles (Ag NPs) through chemical reduction. The Cu-MOF layer selectively captures Pb2+ via ion exchange, delivering a high adsorption capacity of 59.7 mg g-1. This enrichment step effectively transfers dissolved Pb into a uniform solid matrix amenable to laser interrogation. Concurrently, Ag NPs enhance laser-matter coupling through localized surface plasmon resonance (LSPR). Plasma diagnostics revealed that the incorporation of Ag NPs increased the electron temperature by 2.1-fold, while the Pb I 405.8 nm emission intensity reached 4.3 times that of pristine filter paper. Under optimized experimental conditions, this method achieved a limit of detection (LOD) of 44.3 μg L-1 and a relative standard deviation (RSD) of 2.8%. The substrate also maintained excellent selectivity in the presence of competing cations. Recovery tests with river-water samples gave Pb recoveries of 97-104%. By synergistically combining MOF-mediated pre-concentration with AgNPs-assisted emission enhancement, this work offers a sensitive, selective, and field-compatible approach for Pb monitoring in aquatic environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers