Microfluidic integrated nucleic acid test (MINT) enabled by coupling FEN1-aided RPA with wax-purification and bead-carrier.
Zhaoluo Xu, Xingyue Gao, Jinling Huang, Shuyun Pang, Shanshan Wang, Yuanmeng Wang, Liying Feng, Yi Ma,
Department of Clinical Pharmacy, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 210002, China. · Department of Clinical Pharmacy, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 210002, China; State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210002, China. Electronic address: wuhaiping@smu.edu.cn.
Key points
From the paper's conclusion- Here a Microfluidic Integrated Nucleic Acid Test platform (namely, MINT) was proposed for point-of-care molecular diagnostics.
Abstract
To guide timely antibiotic treatment, a tool for quick antimicrobial resistance gene detection is required. Here a Microfluidic Integrated Nucleic Acid Test platform (namely, MINT) was proposed for point-of-care molecular diagnostics. The platform integrates fast nucleic acid extraction based on hybrid wax-phase purification, and DNA amplification based on our newly developed FEN1-aided RPA (FARPA) into a microfluidic chip. The wax-phase stays solid at room temperature, while becomes liquid at >50 °C to allow the wash of inhibitors carried from extraction buffer, thus the chip keeps stable during storage and transportation. The movement of extracted DNA bound with magnetic beads were controlled by a magnet. The beaded DNA was quickly purified during the flow through the wax phase, and the amplification started once the beaded DNA reached to the well for FARPA. The signal from target-positive sample could be readily sensed by a conventional smartphone. The turnaround time is about 40 min from the sample to the result. The platform was validated by detecting the blaKPC-2 resistance gene of Klebsiella pneumoniae (K. pneumoniae) from urine samples with the reliable detection concentration of 500 CFU/mL, achieving 100% agreement for the 29 clinical urine samples (19 positive, 10 negative) with conventional qPCR. It is easy to adapt the MINT to any other pathogen only by designing the corresponding primers and probes for FARPA. It is promising to apply MINT for bed-site antimicrobial resistance screening just after operation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Finger-actuated microfluidic device for point-of-care circulating cell-free nucleic acid extraction.Lab on a chip · 2026
- Field-Deployable Nucleic Acid Testing via Functional Double-Strand to Single-Strand Conversion.Analytical chemistry · 2026
- Recent Advances in Microfluidic-Based Biosensors for Nucleic Acid Detection: From Amplification Strategies to Point-of-Care Diagnostic Devices.SLAS technology · 2026
- An Integrated Centrifugal Microfluidic Point-of-Care Low-Cost Chip for Rapid Pathogen Nucleic Acid Detection and Diagnosis of Bloodstream InfectionsAnalytical Chemistry · 2026
- Rotational Microfluidic Paper-Based Chip Platform Integrating Nucleic Acid Sequence-Based Amplification for Visual and Sensitive Detection of Viable Pathogens.ACS measurement science au · 2026
- A Droplet-Free and Oil-Free Microfluidics Based on Self-Pumping Hydrogel for Point-of-Care Multiplex Digital Nucleic Acid DetectionAnalytical Chemistry · 2026