Talanta

Carbon cloth electrode integrated into a custom 3D-printed architecture for electroanalytical sensing of caffeine.

Fernando C Gallina, Nailson S Rocha, Eduardo M B Valença, Rômulo Dos S Rodrigues, Manoel F da P Almeida, Luís F Basso, Igor G S Oliveira, Thalles P Lisboa,

Faculty of Exact Sciences and Technology, Federal University of Grande Dourados - UFGD, Rodovia João Totó da Câmara, 420, Cidade Universitária, Dourados, MS, 79820-600, Brazil. · Faculty of Exact Sciences and Technology, Federal University of Grande Dourados - UFGD, Rodovia João Totó da Câmara, 420, Cidade Universitária, Dourados, MS, 79820-600, Brazil. Electronic address: willyambarros@ufgd.edu.br.

Computational

Key points

From the paper's conclusion
  • Overall, the results demonstrate the CC electrode mounted in a custom rigid 3D-printed architecture offers a reliable alternative for decentralized electrochemical sensing applications.

Abstract

Routine electrochemical analysis can benefit from customizable cells that accommodate non-planar working-electrode materials. Herein, we report on the development of a highly adaptable electroanalytical platform using a carbon cloth (CC) working electrode integrated into a custom 3D-printed cell. The electrochemical properties of the sensor were evaluated by cyclic voltammetry and electrochemical impedance spectroscopy using a [Fe(CN)6]3-/4- redox probe solution, while operational stability and sensor-to-sensor reproducibility were assessed via chronoamperometry. The integrated CC platform was subsequently applied for the direct quantification of caffeine (CAF) as a model analyte, by square wave voltammetry (SWV) in commercial energy drink formulations, with performance benchmarked against standard method using a paired Student's t-test at a 95% confidence level. Chronoamperometric evaluations of stability and reproducibility using redox probe yielded excellent RSD below 4.2%, confirming robust fabrication and long-term operational reliability to the electrochemical system. Under optimized SWV conditions, the sensor exhibited a wide linear response from 10 to 2000 μmol L-1 and a limit of detection of 3.38 μmol L-1 for CAF. Furthermore, CAF determination by SWV technique demonstrated statistically equivalent analytical accuracy (tcal < tcrit) compared to the reference UV-vis method across all real samples. Overall, the results demonstrate the CC electrode mounted in a custom rigid 3D-printed architecture offers a reliable alternative for decentralized electrochemical sensing applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Carbon cloth electrode integrated into a custom 3D-printed architecture for electroanalytical sensing of caffeine — Science Skim