Key points
From the paper's conclusion- This study demonstrates that rational engineering of magnetic capture architectures can improve fluorescence recovery aptasensing and provides a practical strategy for sensitive AFM1 determination in milk.
Abstract
Aflatoxin M1 (AFM1) contamination in milk and dairy products poses a significant food safety concern, highlighting the need for sensitive and reliable analytical methods. Herein, we developed a fluorescence recovery aptasensor that integrates hierarchical magnetic nano-orbs (HMO) as magnetic capture probes with aptamer-functionalized green-fluorescent silica nanoparticles (Apt-GFSN) as fluorescent signaling probes for AFM1 detection. Three magnetic capture platforms, including magnetic beads (MBs), single-core magnetic nanoparticles (SMN), and HMO, were comparatively evaluated to elucidate the influence of magnetic architecture on probe capture and separation performance. HMO exhibited rapid magnetic separation and enhanced fluorescent probe capture, thereby reducing background fluorescence and improving signal recovery. The sensing mechanism relies on AFM1-induced disruption of the aptamer-complementary DNA duplex, which releases Apt-GFSN from the magnetic assemblies and generates a concentration-dependent fluorescence response. Under optimized conditions, current aptasensor achieved a detection limit of 30 pg/mL and showed high selectivity toward AFM1 over structurally related mycotoxins, veterinary antibiotics, and common milk components. The sensor also exhibited good reproducibility and stability, while analysis of commercial milk samples afforded recoveries of 93.81-100.42%, consistent with ELISA and HPLC results. This study demonstrates that rational engineering of magnetic capture architectures can improve fluorescence recovery aptasensing and provides a practical strategy for sensitive AFM1 determination in milk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fluorescence resonance energy transfer-based aptasensor for rapid detection of aflatoxin M1 in milk.Mikrochimica acta · 2026
- Ultrasensitive on-site detection of aflatoxin M1 in milk using a chitosan-MWCNT-graphene nanocomposite aptasensor with sub-regulatory limit capabilityScientific Reports · 2026
- Development of High-Affinity Monoclonal Antibodies for Aflatoxin M1 Detection in Milk.Journal of agricultural and food chemistry · 2026
- Dual-signal fluorescent-colorimetric aptasensor for tobramycin detection in milk based on fluorescent magnetic nanoparticles and AuNPs.Food chemistry · 2026
- Dual-mode paper-based aptasensor integrated with smartphone readout for visual detection of aflatoxin B1.Talanta · 2026
- Fe3O4/rGO/AuNPs-based fluorescent aptasensor with magnetic collection for determination of Staphylococcus aureus enterotoxin A in milk.Food chemistry · 2026