Ternary metal oxide engineering of screen-printed electrodes for wearable morphine sensing.
Feng Liu, Shengnan Sun, Yong Yu, Xin Ting Zheng, Sherwin Chong Li Tan, Yiqin Wang, Veronica Gurung, Yi Ren,
Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, 138634, Republic of Singapore. · St Edmund's College, University of Cambridge, Cambridge, CB3 0BN, United Kingdom.
Key points
From the paper's conclusion- By introducing a hydrogel interface to solvate and diffuse solid-state morphine to the TMO-modified flexible sensor electrode, our sensor is further integrated into a small form factor wearable platform capable of in-situ, non-invasive detection of solid-state morphine on surfaces such as skin, showing low sensitivity of 2.56 μA cm2 nmol-1 and LoD of 0.28 nmol cm-2 in the dynamic range of 1- 6 nmo
Abstract
Reliable, in-situ detection of opioid drugs remains a critical challenge for healthcare, forensic analysis, and public safety. Herein, we report for the first time a morphine sensor based on a newly designed ternary metal oxide (TMO) with the formula of Mg0.50Ni0.25Zn0.25O. The TMO stabilizing six-coordinated Zn-O in rock-salt MgO and NiO matrix by short-range disorder, exhibits excellent sensitivity, selectivity, and long-term stability towards the electrochemical detection of morphine. The TMO-based morphine sensor shows robust performance across variable environments, in particular a two-fold higher sensitivity than the bare SPCE and achieves a limit of detection (LoD) as low as 0.11 μM with a dynamic range of 0.24 - 54.22 μM. By introducing a hydrogel interface to solvate and diffuse solid-state morphine to the TMO-modified flexible sensor electrode, our sensor is further integrated into a small form factor wearable platform capable of in-situ, non-invasive detection of solid-state morphine on surfaces such as skin, showing low sensitivity of 2.56 μA cm2 nmol-1 and LoD of 0.28 nmol cm-2 in the dynamic range of 1- 6 nmol cm-2.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Synergistic Redox Activity in Transition Metal-Manganese Oxide Nanohybrids for Morphine Electro-AnalysisACS Applied Nano Materials · 2026
- Next-generation electrochemical sensors for opioid detection: from nanostructured interfaces towards real-time clinical monitoring.Analytical methods : advancing methods and applications · 2026
- Simultaneous Detection of Dopamine and Xanthine in Human Sweat by Ultrasensitive MoB-MBene/PVA Sponge-like Hydrogel Grown on a Porous Nickel Substrate.ACS applied bio materials · 2026
- Highly sensitive electrochemical detection and quantification of opium derived morphine sulfate using cysteamine loaded MWCNTs@V2O5 telluride compositeScientific Reports · 2026
- Triple-channel SPR ion-imprinted fiber sensor enabled by MoS₂ thickness-tuned resonance for multiplexed heavy metal ion detectionOptics Letters · 2025
- Bioinspired and Flexible Amino Acid-Based Repairable Hybrid Architecture for Wearable Real-Time Sarin Simulant Detection.ACS sensors · 2026