Diagnostic Accuracy and Clinical Impact of Ocular Fundus Imaging in the Emergency Department: A Systematic Review and Meta-Analysis.
Abdullah Al-Ani, Michelle Pham, David Mikhail, Mayar Alkhawaja, Stephanie Dotchin, Anna Ells, Nancy J Newman, Suresh Subramaniam,
Section of Ophthalmology, Department of Surgery, University of Calgary, Calgary, AB, Canada, T2N 4N1. Electronic address: aalani@ucalgary.ca. · Cumming School of Medicine, University of Calgary, Calgary, AB, Canada, T2N 4N1.
Key points
From the paper's conclusion- We performed a systematic review and meta-analysis to evaluate diagnostic performance, image gradeability, and operational outcomes of emergency department (ED) fundus imaging.
Abstract
Ocular fundus visualization is often limited in emergency departments (EDs), where direct ophthalmoscopy is infrequently performed and may fail to detect vision- or life-threatening pathology. Fundus imaging offers digitally-acquired, remotely-viewable images that may address this gap, but evidence remains fragmented. We performed a systematic review and meta-analysis to evaluate diagnostic performance, image gradeability, and operational outcomes of emergency department (ED) fundus imaging. Following PROSPERO registration (CRD420251126786), we searched ten databases from inception to September 2026, in accordance with PRISMA and PRISMA-DTA guidelines. Studies on diagnostic performance, image gradability, or operational impact of ED fundus imaging were included. Pooled diagnostic sensitivity, specificity, and hierarchical summary receiver operating characteristic area under the curve (HSROC AUC) were estimated using a bivariate random-effects model. Risk of bias was assessed using QUADAS-2 and ROBINS-I, and certainty of evidence using GRADE. In total, 33 studies (6593 patients) met the inclusion criteria. Low-certainty evidence suggested moderate-to-good diagnostic performance. Pooled sensitivity was 0.78 (95% CI: 0.66-0.87), pooled specificity was 0.91 (95% CI: 0.86-0.94), and HSROC AUC was 0.93. Diagnostic performance appeared broadly consistent across imaging modalities, indications, readers, and interpretation settings. Very-low-certainty evidence suggested high pooled image gradability (0.854, 95% CI: 0.796-0.897). In-person ophthalmology consultation was avoided in a pooled 0.416 (95% CI: 0.326-0.512) of consultation requests. Pooled results suggest moderate-to-good diagnostic performance and high image gradability of ED fundus imaging, with possible operational impact. These findings support further evaluation of fundus imaging as a tool to facilitate emergency ophthalmic and teleophthalmology-enabled care pathways.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ocular fundus examination in emergency medicine: an Australian survey of equipment, training, current practice, and clinician perceptions.Eye (London, England) · 2026
- Why aren't we using AI in eye clinics? A systematic review of barriers and solutions in AI-based fundus image diagnostics for ocular diseases.International journal of ophthalmology · 2026
- Diagnostic accuracy of point-of-care ultrasound in adult non-traumatic emergency medicine: an umbrella review.BMC medicine · 2026
- Diagnostic performance of deep learning models in retinal vein occlusion: a systematic review and meta-analysis.Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2026
- Artificial Intelligence in Predicting Systemic Complications From Retinal Findings: A New Frontier in Precision Medicine.Cureus · 2026
- Diagnostic accuracy and reliability of portable visual field-testing devices for detecting manifest glaucomatous visual-field loss: a systematic review and meta-analysis.BMC ophthalmology · 2026