Comparative Analysis of Respirator Fit Factors Using Korean Test Panels and Standardized Korean Headforms.
Hyekyung Seo, Hoyeong Jang, Sungho Kim
Department of Health Technology, Shinhan University, Uijeongbu-City, Gyeonggi-Do, Republic of Korea. · OSHRI, Ulsan, Republic of Korea.
Key points
From the paper's conclusion- The Korean fit test panel appears to represent population-specific facial dimensions and shows potential for respirator evaluation under the tested conditions. However, differences between participants and headform outcomes indicate the need for improved headform fidelity to enhance test reliability.
Abstract
BACKGROUND: Fit testing is essential to evaluate the effectiveness of respiratory protective equipment for ensuring occupational safety. The Republic of Korea currently lacks a standardized fit test panel that reflects domestic facial characteristics, although international guidelines emphasize its establishment. This study aimed to validate a Korean fit test panel developed according to international standards and to examine the consistency of fit test results between human participants and headforms with comparable facial dimensions. METHODS: The panel was developed using facial anthropometric data from 11,429 adults in the Size Republic of Korea database based on ISO 16976-2:2022(E). Fifty participants representing the panel categories underwent quantitative fit testing with various respirator models. Fit test pass rates of human participants and headforms were evaluated against the U.S. National Personal Protective Technology Laboratory ( 2015) criterion of 64-76% to determine the panel's applicability. RESULTS: Participants with medium-to-large faces achieved significantly higher fit factors with large respirators (p < 0.05), whereas those with small faces exhibited lower fit for small-sized models. Significant differences were observed across respirator size categories (p < 0.05), with full-face types showing higher pass rates than half-face types. Human fit tests exceeded the National Personal Protective Technology Laboratory criterion (76-100%), supporting the panel's international applicability. In contrast, headform-based testing produced lower fit factors, particularly for small respirators. Intraclass correlation coefficient analysis revealed poor agreement (<16%) between human and headform results. CONCLUSION: The Korean fit test panel appears to represent population-specific facial dimensions and shows potential for respirator evaluation under the tested conditions. However, differences between participants and headform outcomes indicate the need for improved headform fidelity to enhance test reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Active-flow systems enhance respirator fit success in children: a comparative study with standard disposable models.Frontiers in public health · 2026
- Utilization of a smartphone-based app for N95 respirator fit recommendations: A feasibility study assessing app respirator selection accuracy and usability compared to standard fit test processes.Journal of occupational and environmental hygiene · 2026
- Evaluating a rapid fit-testing method for N95 respirators in Chinese healthcare workers: a paired crossover simulation and diagnostic agreement study.Frontiers in public health · 2026
- Pre‐operative three‐dimensional face scans for predicting difficult facemask ventilation: a prospective development studyAnaesthesia · 2026
- Prospective development and validation of an objective classification for difficult facemask ventilation: the MASCAN scoreAnaesthesia · 2026
- Observational evaluation of children's respirator donning ability in Indonesia and Nepal.Scientific reports · 2026