A near-infrared fluorescent probe with large stokes shift for rapid and sensitive detection of genotoxic impurity ethyl triflate in pharmaceuticals.
Aiping Xing, Ao Shen, Yanjun Zhu, Sijia Li, Bin Zhang, Jing Wang, Dai Zeng, Juan Yuan
School of Pharmacy, Henan University of Chinese Medicine, Zhengzhou 450046, PR China. · School of Pharmacy, Henan University of Chinese Medicine, Zhengzhou 450046, PR China. Electronic address: zengdai@hactcm.edu.cn.
Key points
From the paper's conclusion- Therefore, the accurate detection of ET has become an increasingly important research direction.
Abstract
Ethyl triflate (ET), a typical genotoxic impurity in pharmaceuticals, poses a significant risk to patient health. Therefore, the accurate detection of ET has become an increasingly important research direction. Although several fluorescent probes have been developed for the detection of ET, probes that simultaneously achieve simplicity, rapidity, and high sensitivity are still urgently needed. This paper successfully developed a near-infrared (NIR) fluorescent probe NRK, by incorporating a quinoline fluorophore into the xanthene skeleton. The structure of NRK was characterized using 1H NMR, 13C NMR, and ESI-HRMS spectroscopic analysis. NRK features a 4 s response time, 0.134 μM detection limit, and 170 nm Stokes shift, showing promising potential for practical sensing applications. ESI-HRMS analysis, together with temperature- and solvent-dependent fluorescence measurements, experimentally confirmed the N-alkylation response of NRK toward ET, while DFT calculations provided a complementary computational framework supporting the proposed PET-blockade and TICT-formation mechanism. The probe NRK enables the effective quantitative detection of ET in pharmaceuticals, with a recovery rate ranging from 98.4% to 102.3% and a relative standard deviation (RSD) <3%. Simultaneously, a portable intelligent detection device has been constructed to realize on-site visual and quantitative detection of ET in pharmaceuticals based on the visual response property of NRK to ET, achieving an accuracy rate ranging from 97.0% to 104.0% and precision with 1.0% to 5.6% of RSD.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Red-emissive fluorescent probes based on PET mechanism for highly sensitive detection and multi-scenario imaging of thiophenol.Food chemistry · 2026
- Screening-guided identification of a near-infrared fluorogenic reporter for portable chloramphenicol aptasensing.Chemical communications (Cambridge, England) · 2026
- A Nanoengineered Red‐Emissive Ionic Liquid‐Based Optode for “OFF–ON–OFF” Dual‐Transduction Modes Detection of Dextran Sulfate and Protamine SulfateChemNanoMat · 2026
- Recent Advances in Near-Infrared Probes for Monitoring Drug Treatment Responses: Toward Efficacy Evaluation and High-Throughput Screening.Chemical & biomedical imaging · 2026
- Turn-On Near-Infrared Lateral Flow Immunoassay with Synergistic Energy Transfer for Direct and Ultrasensitive Detection in Complex Matrices.Analytical chemistry · 2026
- Disulfide-Bridged Pyrene-Dicyanoisophorone Dyad for Cross-Validated Dual-Channel Fluorescent Detection of Dithiothreitol in Biological Fluids.ACS applied materials & interfaces · 2026