Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

Open-set FTIR mixed-gas recognition with target-gas label retention and unknown-component indication.

Nan Deng, Jingjing Tong, Liang Xu, Ling Jin, Sheng Li, Yongfeng Sun, Hanyang Xu, Min He,

Institutes of Physical Science and Information Technology, Anhui University, Hefei, 230601, Anhui, PR China; Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China. · Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China. Electronic address: jjtong@aiofm.ac.cn.

Key points

From the paper's conclusion
  • These results demonstrate that ReLaSG maintains high joint-decision performance under overlapping absorptions of target gases and unknown gases, providing a spectral-evidence-constrained, non-mutually exclusive joint-decision approach for FTIR mixed-gas monitoring in open environments.

Abstract

In practical Fourier transform infrared (FTIR) monitoring of mixed gases, it is difficult for training data to cover all gas species that may occur in the field. The occurrence of unmodeled gases may signal process fluctuations, equipment leakage, or unexpected risk events. When the absorptions of target and unknown gases are superimposed in the same spectrum, reporting only the target-gas recognition results may mask the contribution of unknown-gas absorptions, whereas rejecting the entire spectrum as unknown may discard information on truly present target gases. To address this problem, we propose a Residual, Label-Attentive, and Spectral-Evidence Gating (ReLaSG) framework for open-set mixed-gas recognition, which simultaneously retains target-gas labels and indicates the presence of unknown components. ReLaSG integrates label-attentive responses, convolutional autoencoder reconstruction residuals, and spectral-shape similarity in characteristic absorption regions to model target-gas evidence, unknown-gas absorption deviations, and local spectral consistency, respectively. On a dataset containing six target-gas classes, four unknown-gas classes, and background samples, ReLaSG achieved an overall joint exact matching rate excluding background samples of 0.9748 and a scenario-level macro-averaged joint exact matching rate of 0.9781. In the coexistence scenario involving both target and unknown gases, ReLaSG achieved a joint exact matching rate of 0.9689, outperforming representative open-set recognition baselines. These results demonstrate that ReLaSG maintains high joint-decision performance under overlapping absorptions of target gases and unknown gases, providing a spectral-evidence-constrained, non-mutually exclusive joint-decision approach for FTIR mixed-gas monitoring in open environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Open-set FTIR mixed-gas recognition with target-gas label retention and unknown-component indication — Science Skim