Water-cluster size estimation from OH-stretching infrared spectra.
Yabo Sun, Guohua Wang, Fuhao Zhang, Lisong Yang, Jing Nie
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China. · School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China. Electronic address: jingnie@buaa.edu.cn.
Key points
From the paper's conclusion- Application to attenuated total reflection Fourier transform infrared (ATR-FTIR) spectra collected during condensation showed an overall decrease in model-equivalent cluster size with increasing distance from the cooled surface.
Abstract
The development of humidity characterization is moving beyond macroscopic quantities such as relative humidity, dew point and water-vapor concentration. Near saturation and during early condensation, molecular aggregation provides a link between conventional humidity quantities and the microscopic organization of water. This study develops an infrared spectral approach for estimating water-cluster size from the OH-stretching band. A theoretical calibration set containing 156 infrared spectra was constructed for 57 cluster sizes sampled between 1 and 150 water molecules. Nine descriptors describing spectral position, normalized band area, free-OH contribution and band shape were extracted and converted into cluster-size estimates using an ensemble of support vector regression (SVR) and Extra Trees regression. Model performance was evaluated by leaving out all spectra sharing the same molecular number. The resulting model achieved an R2 of 0.939, an MAE of 5.70 water molecules and an RMSE of 8.32 water molecules, with 80.13% of the estimates falling within ±10 water molecules. An additional nested grouped assessment of model selection gave an R2 of 0.935 and an MAE of 5.90 water molecules. Two published size-resolved experimental spectra provided illustrative comparisons for 24- and 32-molecule clusters, with estimates of 17.29 and 38.99 water molecules, respectively. Application to attenuated total reflection Fourier transform infrared (ATR-FTIR) spectra collected during condensation showed an overall decrease in model-equivalent cluster size with increasing distance from the cooled surface. The proposed framework links molecular-scale information encoded in OH-stretching spectra with macroscopic humidity measurements, providing a basis for cluster-resolved characterization of early condensation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physiological Parameter Estimation from Reduced-Wavelength Hyperspectral Data: A Model-Based StudyCurrent Directions in Biomedical Engineering · 2026
- Experimental determination of structural motifs of interference-free water undecamer cluster (H2O)11Nature Communications · 2025
- Multi-source fusion of NIR and UV spectroscopy with refractometry for pooled prediction of total flavonoids, total polyphenols and solids content in herbal water extracts.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Atomic-Scale View of Water Adsorption on the TiO2 Anatase Surface: From Isolated Molecules to Multilayers.ACS applied materials & interfaces · 2026
- The next step in microsolvation of water by CO2: study of water-(CO2)3 by quantum chemistry calculations and combined microwave and infrared spectroscopy.Physical chemistry chemical physics : PCCP · 2026
- Dielectric and Measurement-Domain Feature Fusion for Machine Learning-Based Broadband Microwave Sensing: Application to Ethanol Concentration Estimation.Sensors (Basel, Switzerland) · 2026