Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

Long-term physicochemical and spectroscopic validation of a microfabricated Raman chip for biological reference samples.

Markus Salbreiter, Christof Neumann, Annette Wagenhaus, Susanne Pahlow, Anja Silge, Andrey Turchanin, Jürgen Popp, Thomas W Bocklitz

Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena 07743, Germany; InfectoGnostics Research Campus Jena, Center of Applied Research, 07743 Jena, Germany. · Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena 07743, Germany.

Key points

From the paper's conclusion
  • Here, we systematically evaluate the long-term physicochemical and spectroscopic stability of a previously established microfabricated aluminium-coated silicon Raman chip for biological reference applications.

Abstract

The lack of biologically relevant reference materials remains a major challenge for the standardization of Raman spectroscopy. Here, we systematically evaluate the long-term physicochemical and spectroscopic stability of a previously established microfabricated aluminium-coated silicon Raman chip for biological reference applications. The platform combines an aluminium-coated Raman-compatible measurement surface with a microscope slide-compatible format for integration into conventional Raman microscopy workflows. Longitudinal X-ray photoelectron spectroscopy revealed comparatively small changes in the surface composition of individual aluminium-coated chips stored at room temperature or under refrigerated conditions over six months, whereas more pronounced surface modifications were observed for the chip investigated under humid storage conditions. Using bacterial endospores as a model biological system, longitudinal Raman measurements at 532 and 785 nm excitation showed preservation of characteristic Raman fingerprints without systematic spectral drift or substrate-derived interference. While increasing fluorescence increasingly obscured the Raman signals at 532 nm after approximately four weeks, characteristic Raman spectra remained detectable at 785 nm throughout the twelve-week monitoring period. These findings provide initial evidence of temporal physicochemical and spectroscopic stability within the investigated chip preparations and support further validation of the platform for biological Raman reference applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers