Long-term physicochemical and spectroscopic validation of a microfabricated Raman chip for biological reference samples.
Markus Salbreiter, Christof Neumann, Annette Wagenhaus, Susanne Pahlow, Anja Silge, Andrey Turchanin, Jürgen Popp, Thomas W Bocklitz
Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena 07743, Germany; InfectoGnostics Research Campus Jena, Center of Applied Research, 07743 Jena, Germany. · Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena 07743, Germany.
Key points
From the paper's conclusion- Here, we systematically evaluate the long-term physicochemical and spectroscopic stability of a previously established microfabricated aluminium-coated silicon Raman chip for biological reference applications.
Abstract
The lack of biologically relevant reference materials remains a major challenge for the standardization of Raman spectroscopy. Here, we systematically evaluate the long-term physicochemical and spectroscopic stability of a previously established microfabricated aluminium-coated silicon Raman chip for biological reference applications. The platform combines an aluminium-coated Raman-compatible measurement surface with a microscope slide-compatible format for integration into conventional Raman microscopy workflows. Longitudinal X-ray photoelectron spectroscopy revealed comparatively small changes in the surface composition of individual aluminium-coated chips stored at room temperature or under refrigerated conditions over six months, whereas more pronounced surface modifications were observed for the chip investigated under humid storage conditions. Using bacterial endospores as a model biological system, longitudinal Raman measurements at 532 and 785 nm excitation showed preservation of characteristic Raman fingerprints without systematic spectral drift or substrate-derived interference. While increasing fluorescence increasingly obscured the Raman signals at 532 nm after approximately four weeks, characteristic Raman spectra remained detectable at 785 nm throughout the twelve-week monitoring period. These findings provide initial evidence of temporal physicochemical and spectroscopic stability within the investigated chip preparations and support further validation of the platform for biological Raman reference applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-Perturbative Bacterial Identification Directly From Solid Agar Plates Using Raman Micro-Spectroscopy and Machine Learning.Small methods · 2026
- Magnetron-Sputtered Gold Substrates with Controlled Surface Grains for Multimodal SERS–AFM SensingChemosensors · 2026
- Time-Dependent Molecular Changes in Preserved Rat Corneas Revealed by Raman SpectroscopyApplied Sciences · 2026
- Advances and Challenges in Raman and Surface-Enhanced Raman Spectroscopy for Biological SystemsACS Applied Bio Materials · 2026
- Stainless Steel vs Calcium Fluoride for biomedical Raman SpectroscopybioRxiv · 2026
- How laser wavelength and polarization shape the molecular Raman response enhanced by capped Ag nanoparticle chains.Physical chemistry chemical physics : PCCP · 2026