Quinoxaline-mediated backbone modification Tunes Fe3+-selective versus Fe3+/Cu2+ dual spectral response in Schiff-Base UV-vis probes.
Zhen-E Chen, Wei Guo, Qiu-Feng Chen, Ya-Di Gao, Hai Zhang
School of Chemistry and Chemical Engineering, Academician Workstation, Zunyi Normal College, Zunyi, 563006, China. Electronic address: zhenechen@vip.sina.com. · School of Chemistry and Chemical Engineering, Academician Workstation, Zunyi Normal College, Zunyi, 563006, China.
Key points
From the paper's conclusion- Overall, quinoxaline-mediated backbone modification (including π-extension, altered rigidity, and electronic redistribution) shifts the sensing behavior from Fe3+-selective to Fe3+/Cu2+ dual-spectral response.
Abstract
Distinguishing Fe3+ from Cu2+ is challenging, as both cations exhibit similar coordination preferences toward N/O-rich chelating sites. Herein, two structurally related Schiff-base chemosensors (TPCN and TPQCN) with identical chelating motifs but modified π-backbones were constructed to probe backbone-dependent metal-ion sensing. The short-π-backbone TPCN displays selective absorbance turn-on for Fe3+ with a limit of detection (LOD) of 2.28 μM. Upon incorporation of a quinoxaline moiety, TPQCN exhibits dual spectral responsiveness toward Fe3+ and Cu2+; however, its Cu2+-related response is considerably weaker, accompanied by reduced sensitivity (LODs = 8.91 μM for Fe3+ and 23.54 μM for Cu2+) and compromised anti-interference capability, and TPQCN cannot discriminate the two ions in mixtures. Reliable association constants could not be determined because of incomplete spectral saturation and secondary-species formation at high metal-ion equivalents; fitted apparent values are provided in the Supporting Information for reference only and should not be used for quantitative comparison. DFT calculations on the free probes indicate localized frontier orbitals in TPCN and a more delocalized electron distribution in TPQCN, providing only qualitative mechanistic insight, as metal-complex optimizations were not performed. TPCN was evaluated in tap-water and lake-water matrices, affording spike recoveries of 95-109%. Overall, quinoxaline-mediated backbone modification (including π-extension, altered rigidity, and electronic redistribution) shifts the sensing behavior from Fe3+-selective to Fe3+/Cu2+ dual-spectral response. This gain in multi-ion responsiveness comes at the expense of sensitivity and ion-selectivity rather than achieving Fe3+/Cu2+ discrimination, revealing a practical design trade-off for probes targeting chemically similar metal ions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Channel-selective, dual-channel colorimetric detection of Fe3+ and fluorometric sensing of CN- using an anthracene Schiff base chemosensor.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Synthesis and computational studies of 4-fluoro-N'-(pyridine-2-ylmethylene)benzohydrazide as a multi-metal binding agent capable of chelating transition metals (Zn2+, Cu2+, Co2+) with high affinity.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Schiff Base–Derived Colorimetric Chemosensor for Fe³⁺ Detection: Synthesis, Mechanistic Insights, and Real‐World Applications in Water Quality MonitoringInternational Journal of Analytical Chemistry · 2026
- A heterocyclic chalcone-based fluorescent chemosensor for selective Cu(II) detection: mechanistic insights and preliminary bacterial imaging applications.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Smart dual sensors enable Cu2+ and Fe3+ ions detection in water at low levels.Journal of materials chemistry. B · 2026
- New Coumarin-Schiff Bases: Synthesis, Electrochemical Behavior, Anion/Cation Sensing Capacities, Spectroscopic Analysis, DFT Studies and NLO Properties.Journal of fluorescence · 2026