Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

Quinoxaline-mediated backbone modification Tunes Fe3+-selective versus Fe3+/Cu2+ dual spectral response in Schiff-Base UV-vis probes.

Zhen-E Chen, Wei Guo, Qiu-Feng Chen, Ya-Di Gao, Hai Zhang

School of Chemistry and Chemical Engineering, Academician Workstation, Zunyi Normal College, Zunyi, 563006, China. Electronic address: zhenechen@vip.sina.com. · School of Chemistry and Chemical Engineering, Academician Workstation, Zunyi Normal College, Zunyi, 563006, China.

Key points

From the paper's conclusion
  • Overall, quinoxaline-mediated backbone modification (including π-extension, altered rigidity, and electronic redistribution) shifts the sensing behavior from Fe3+-selective to Fe3+/Cu2+ dual-spectral response.

Abstract

Distinguishing Fe3+ from Cu2+ is challenging, as both cations exhibit similar coordination preferences toward N/O-rich chelating sites. Herein, two structurally related Schiff-base chemosensors (TPCN and TPQCN) with identical chelating motifs but modified π-backbones were constructed to probe backbone-dependent metal-ion sensing. The short-π-backbone TPCN displays selective absorbance turn-on for Fe3+ with a limit of detection (LOD) of 2.28 μM. Upon incorporation of a quinoxaline moiety, TPQCN exhibits dual spectral responsiveness toward Fe3+ and Cu2+; however, its Cu2+-related response is considerably weaker, accompanied by reduced sensitivity (LODs = 8.91 μM for Fe3+ and 23.54 μM for Cu2+) and compromised anti-interference capability, and TPQCN cannot discriminate the two ions in mixtures. Reliable association constants could not be determined because of incomplete spectral saturation and secondary-species formation at high metal-ion equivalents; fitted apparent values are provided in the Supporting Information for reference only and should not be used for quantitative comparison. DFT calculations on the free probes indicate localized frontier orbitals in TPCN and a more delocalized electron distribution in TPQCN, providing only qualitative mechanistic insight, as metal-complex optimizations were not performed. TPCN was evaluated in tap-water and lake-water matrices, affording spike recoveries of 95-109%. Overall, quinoxaline-mediated backbone modification (including π-extension, altered rigidity, and electronic redistribution) shifts the sensing behavior from Fe3+-selective to Fe3+/Cu2+ dual-spectral response. This gain in multi-ion responsiveness comes at the expense of sensitivity and ion-selectivity rather than achieving Fe3+/Cu2+ discrimination, revealing a practical design trade-off for probes targeting chemically similar metal ions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers