Cascade-activated fluorescent probe for temporal imaging of H2S and microviscosity dynamics under inflammatory stress.
Yuxi Ding, Haijiao Wu, Zhiyun Zhang, Lifang Guo
Key Laboratory for Advanced Materials and Feringa Nobel Prize Scientist Joint Research Center, Institute of Fine Chemicals, School of Chemistry & Molecular Engineering, East China University of Science & Technology, Shanghai 200237, China. · Key Laboratory for Advanced Materials and Feringa Nobel Prize Scientist Joint Research Center, Institute of Fine Chemicals, School of Chemistry & Molecular Engineering, East China University of Science & Technology, Shanghai 200237, China. Electronic address: guolf@ecust.edu.cn.
Key points
From the paper's conclusion- In summary, PPAC-SNO2 enables dual-channel visualization of H2S and viscosity with large spectral separation and low crosstalk, providing a useful tool for probing time-dependent chemical signaling and microenvironment change during inflammatory stress.
Abstract
Inflammation is a critical pathological process closely associated with redox imbalance, metabolic dysregulation, and microenvironment changes. Hydrogen sulfide (H2S) and microviscosity are both involved in inflammation stress, but their temporal relationship remains unclear. Existing H2S-viscosity dual-responsive probes mainly provide parallel readouts or are often limited by insufficient spectral separation. Herein, we developed a cascade-activated fluorescent probe PPAC-SNO2 for sequential detection of H2S and viscosity with a large spectral separation of 178 nm. Upon reaction with H2S, PPAC-SNO2 undergoes sulfonate cleavage to release PPAC-OH, producing red emission at 630 nm. Under high-viscosity conditions, the excited-state conformational evolution of PPAC-OH is restricted, generating blue-green emission at 452 nm. The large spectral separation minimizes channel crosstalk and enables accurate dual-channel imaging. In the lipopolysaccharide/aminooxyacetic acid group, where endogenous H2S biosynthesis was inhibited, delayed viscosity elevation was still observed, indicating that viscosity elevation is associated with inflammatory stress. In summary, PPAC-SNO2 enables dual-channel visualization of H2S and viscosity with large spectral separation and low crosstalk, providing a useful tool for probing time-dependent chemical signaling and microenvironment change during inflammatory stress.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Probe for the Simultaneous Imaging of Hydrogen Polysulfides (H2S4) and Viscosity in Drug-Induced InjuryAnalytical Chemistry · 2026
- Dual-functional fluorescent probe for rapid monitoring of bisulfite and viscosity in biosystem and foods.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- A dual-responsive fluorescent probe for 4-methylbenzenethiol detection and viscosity imaging of pathological processes.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- A dual-targeted mitochondria and lipid droplets near-infrared probe for visualizing viscosity and sulfur dioxide fluctuations during inflammatory microenvironment.Mikrochimica acta · 2026
- A novel water‐soluble near‐infrared fluorescent probe for monitoring viscosity fluctuations in plants and zebrafish under abiotic stressesSmart Molecules · 2026
- Dual-channel long afterglow imaging of mitochondrial viscosity and hydrogen peroxide in living cells.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026