A microfiber sensor for high-sensitivity detection of trace phosphate ions in tap water and serum samples.
Wei Wang, Zhihao Zuo, Xudong Hou, Kexin Ji, Lijiao Zu, Xinghu Fu, Shi Qiu, Jinhui Yuan,
School of Information Science and Engineering, the Key Laboratory for Special Fiber and Fiber Sensor of Hebei Province, Yanshan University, Qinhuangdao, 066004, China. · School of Information Science and Engineering, the Key Laboratory for Special Fiber and Fiber Sensor of Hebei Province, Yanshan University, Qinhuangdao, 066004, China. Electronic address: qiushi325@ysu.edu.cn.
Key points
From the paper's conclusion- These findings suggest that the propo-sed microfiber sensor has potential for drinking water monitoring and clinical diagnostics.
Abstract
Phosphate ions are essential for biological and environmental processes; however, their excessive accumulation in water bodies can lead to eutrophication, and their entry into the human body through the food chain can cause metabolic disorders and other health issues. Therefore, developing a rapid, sensitive, and precise detection method is crucial for controlling drinking water pollution and monitoring human health. To address this critical issue, this paper proposes a single mode-tapered multimode-single mode (STMS) fiber sensor for trace phosphate ion detection. Experimental results show that the proposed fiber sensor exhibits good spectral stability, with a specific detection time for phosphate ions of less than 10 min. In tap water sample testing, the STMS microfiber sensor exhibits a low limit of detection (LoD) of 0.25 pM and good selectivity, with minimal cross-reactivity to common anions in water, including cl-, SO₄2-, CO₃2-, and NO₃-. Furthermore, results for the detection of phosphate ion in serum samples also demonstrated a low LoD of 0.6 pM, which is far below the normal physiological phosphate concentration range in adult serum or plasma (0.81 to 1.45 mmol/L) as defined by the National Institutes of Health. These findings suggest that the propo-sed microfiber sensor has potential for drinking water monitoring and clinical diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Solid-Contact Ion-Transfer Stripping Voltammetric Sensor for Reagent-Free Orthophosphate Determination in Tap Water.Sensors (Basel, Switzerland) · 2026
- An integrated opto-fluidic miniaturized multimodal spectroscopic sensing platform for multiplexed electrolyte detection in blood serum.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- A Molecular Logic Gate-Based Optical Sensor for Rapid Phosphate Detection in Environmental WatersACS ES&T Engineering · 2026
- Microfluidic Chips for Rapid On-Site Detection of both Total Nitrogen and Total Phosphorus in Water Quality MonitoringAnalytical Chemistry · 2026
- Paper-based microfluidic electrochemical sensor for chloride ion and uric acid detection in sweatTalanta · 2025
- High-throughput microplate-based optical assay of salivary phosphates using image capturing detection.Analytical methods : advancing methods and applications · 2026