3D-printed titanium trail plate for repair of diaphyseal fracture of long bones in dogs.
Luciane Dos Reis Mesquita, Sheila Canevese Rahal, Washington Takashi Kano, André Luiz Jardini Munhoz, Aline Ryie Toma, Maria Jaqueline Mamprim, Guilherme Rech Cassanego
Department of Veterinary Surgery and Animal Reproduction, School of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu, São Paulo, Brazil. Electronic address: lr.mesquita@unesp.br. · Department of Veterinary Surgery and Animal Reproduction, School of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu, São Paulo, Brazil.
Key points
From the paper's conclusion- In conclusion, this preliminary case series suggests that modified DMLS-manufactured titanium trail plate was clinically feasible for selected canine diaphyseal fractures.
Abstract
The trail plate is a modular system consisting of a trail bar and synthesis modules made of stainless steel, originally developed for humans. This study aimed to evaluate the applicability and effectiveness of a modified trail plate for the treatment of long bone fractures in dogs. Initially, the trail plate was designed by using FEA to set the final model. Three trail plate sizes were designed according to corresponding locking screw diameters. The designs were created using computer-aided design software, and 3D models were produced from the commercial Ti-6Al-4 V powder via direct metal laser sintering (DMLS). The trail plate application included radius/ulna (n = 5), femur (n = 7), and tibia/fibula (n = 7). Radiographic bone healing occurred within 60 days in 100% of radius/ulna fractures, within 90 days in 70% of tibia/fibula fractures, and between 30 and 120 days postoperatively in femoral fractures. Radius/ulna fractures exhibited minimal callus formation, and all animals were free of lameness by 60 days. Femoral fractures showed mostly moderate callus formation, with lameness resolved in 57% of dogs by 60 days. In tibia/fibula fractures, callus ranged from minimal to abundant, with lameness resolved in six dogs by 60 days. Complications occurred in 36.8% of cases, primarily due to trail bar displacement of the module; only one case involved implant failure. In conclusion, this preliminary case series suggests that modified DMLS-manufactured titanium trail plate was clinically feasible for selected canine diaphyseal fractures. However, fixation-related complications indicate that further design optimization and controlled biomechanical studies are necessary before broader recommendation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Internal Fixation Using Vitcone® Locking-Plate System for Fractures of Radius and Ulna in Toy- and Small-Breed Dogs: A Retrospective Two-Center Clinical Study.Animals : an open access journal from MDPI · 2026
- Absorbable Miniplates for Treatment of Mandibular Fractures in 3 Dogs.Journal of veterinary dentistry · 2026
- Stabilization of canine ilial body fractures using an anatomically contoured locking iliac plate: A short retrospective case series.PloS one · 2026
- Review on lower limb bone fracture fixation: biomechanics, design, and advancements in additive manufacturing for implantsMaterials & Design · 2025
- Development and biomechanical study of a novel tibial external fixation device in synthetic tibial fracture models.Clinical biomechanics (Bristol, Avon) · 2026
- A novel 3D-printed patient-specific limb-sparing radial endoprosthesis for treatment of primary osteosarcoma in a Great Dane.Veterinary surgery : VS · 2026