Research and practice in thrombosis and haemostasis

Characteristics of pediatric central venous catheter malfunction and subsequent catheter-related deep vein thrombosis.

Natasha S Bala, Zaineb Boulil, Emily Krava, Char Witmer, Sarah H O'Brien, Lingyun Ji, Guy Young, Julie Jaffray

Center for Cancer and Blood Disorders, Department of Pediatrics, Phoenix Children's Hospital, Phoenix, Arizona, USA. · Research Administration Department, Rady Children's Hospital, San Diego, California, USA.

Key points

From the paper's conclusion
  • CVC malfunction is common and associated with several modifiable catheter-related factors. Six percent of malfunctioning CVCs develop CR-DVT, and repeated t-PA use and persistent CVC dysfunction may warrant further evaluation for underlying thrombosis.

Abstract

BACKGROUND: Central venous catheters (CVCs) are increasingly placed in children; however, malfunction and deep vein thrombosis (DVT) are reasons for frequent removal. OBJECTIVES: The objective of this study was to evaluate variables associated with CVC malfunction and, subsequently, the development of CVC-related DVT (CR-DVT). METHODS: This subanalysis of the multicenter, prospective Clot Incidence Rates in Central Lines study enrolled children aged 6 months to <18 years with newly placed peripherally inserted central catheters or tunneled lines from 2013 to 2018. Time from CVC placement to first malfunction was analyzed in the full cohort using univariable and multivariable Weibull regression. Among CVCs that malfunctioned, time from first malfunction to CR-DVT was analyzed to assess tissue plasminogen activator (t-PA) use and subsequent thrombosis. RESULTS: Malfunction occurred in 380/1951 CVCs (19.5%). In multivariable analysis, prior CVC use (hazard ratio [HR], 1.51; 95% CI, 1.19-1.90; P = .001), multilumen catheters (HR, 2.89; 95% CI, 2.30-3.65; P < .001), and >2 insertion attempts (HR, 2.21; 95% CI, 1.42-3.45; P < .001) were associated with a higher risk of malfunction, whereas catheter size >4 French and interventional radiology placement were associated with a lower risk. Among malfunctioning CVCs, 22/380 (5.8%) developed CR-DVT, with a median time to CR-DVT of 6 days after malfunction. Increasing t-PA use showed a nonsignificant trend toward higher subsequent CR-DVT. CONCLUSION: CVC malfunction is common and associated with several modifiable catheter-related factors. Six percent of malfunctioning CVCs develop CR-DVT, and repeated t-PA use and persistent CVC dysfunction may warrant further evaluation for underlying thrombosis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers