A miniaturized chemiluminescent thrombin generation assay to assess the effect of APCC in persons with hemophilia A with inhibitors: an observational study.
Aernoud P Bavinck, Theodora J Steeghs, Lisa van Engelshoven, Nerissa M M Coolen, Claudia J van de Ridder, Beata Baran, Jerzy Windyga, Nicole M A Blijlevens,
Department of Hematology, Radboud University Medical Centre, The Netherlands. · Enzyre, Nijmegen, The Netherlands.
Key points
From the paper's conclusion- The microfluidic-TGAlum detects the hemostatic effects of APCC treatment in persons with hemophilia A with inhibitors. Assay-specific differences in TGA response may complicate APCC monitoring in persons with hemophilia A with inhibitors. Our findings underscore the need for further mechanistic TGA studies and standardization.
Abstract
BACKGROUND: Monitoring of bypassing agents in persons with hemophilia A with inhibitors is complicated, especially when multiple treatment modalities are combined. The thrombin generation assay (TGA) might address these issues but is hampered by limited availability and standardization. OBJECTIVES: To assess the performance of a novel microfluidic chemiluminescent TGA (microfluidic-TGAlum) to monitor the effect of anti-inhibitor coagulant complex (APCC) in persons with hemophilia A with inhibitors. METHODS: The microfluidic-TGAlum was used in factor VIII (FVIII)-deficient plasma samples with different concentrations of FVIII inhibitors spiked with APCC and samples from 6 participants with hemophilia A with inhibitors before and after APCC administration. Peak height (PH), area under the curve (AUC), velocity index (VI), and lag time were compared with results obtained using the Ceveron TGA with reagent B (TGACeveron-RB). RESULTS: Increasing concentrations of APCC spiked in FVIII-deficient plasma significantly increased PH, AUC, and VI and shortened lag time in the microfluidic-TGAlum, with strong correlation with TGACeveron-RB outcomes (r = 0.92-0.97). Microfluidic-TGAlum outcomes improved similarly after administering APCC to participants with hemophilia A with inhibitors, although thrombin generation exceeded normal values, with PH reaching 174% of that observed in normal pooled plasma. In contrast, the TGACeveron-RB displayed persistently low thrombin generation and weak correlation with microfluidic-TGAlum (r = 0.28-0.52). Exploratory follow-up experiments revealed that accumulation of prothrombin in plasma of participants with hemophilia A with inhibitors and low phospholipid concentration in the TGACeveron-RB might explain this discrepancy. CONCLUSIONS: The microfluidic-TGAlum detects the hemostatic effects of APCC treatment in persons with hemophilia A with inhibitors. Assay-specific differences in TGA response may complicate APCC monitoring in persons with hemophilia A with inhibitors. Our findings underscore the need for further mechanistic TGA studies and standardization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thrombin Generation Assays: Possibilities and LimitationsHämostaseologie · 2026
- Single-Step Microfluidic Anti-Factor Xa Assay: Development and Clinical Evaluation in Patients on Low-Molecular-Weight Heparin.Sensors (Basel, Switzerland) · 2026
- Tissue Factor/Factor XIa Dual-activated Thrombin Generation is Able to Reliably Measure Thrombin Generation at All Hemophilia A Disease Severities.TH open : companion journal to thrombosis and haemostasis · 2026
- A Modified Intrinsic Thrombin Generation Assay for Functional Assessment of Factor and Non-Factor Therapies in HemophiliaBiomedicines · 2026
- A rapid ADAMTS13 activity assay using a portable readout device.Blood vessels, thrombosis & hemostasis · 2026
- Thrombin Generation in Critically Ill Adults: A Systematic Review of Venous Thromboembolism and Pharmacological Thromboprophylaxis.Journal of thrombosis and haemostasis : JTH · 2026