Respiratory medicine

Endobronchial Valves for Persistent Air Leaks in Necrotizing Pneumonia and Complex Pleuropulmonary Infections: A National Analysis of Safety and Efficacy.

Falah Abu Hassan, Yacoub Majdoubeh, Lisa Jarnagin, Raed Alalawi

Division of Pulmonary and Critical Care Medicine, The University of Arizona College of Medicine - Phoenix, Phoenix, Arizona, USA. Electronic address: falahiabuhassan@hotmail.com. · Department of General Surgery, Altnagelvin Hospital, Londonderry, Northern Ireland, United Kingdom.

Key points

From the paper's conclusion
  • Among EBV-treated hospitalizations, Complex Infection was not significantly associated with composite clinical failure after adjustment, though device extraction rates were notably higher in this cohort. Mechanical ventilation was associated with clinical failure in the main adjusted model, and MRSA was associated with clinical failure in a separate pathogen-adjusted analysis.

Abstract

BACKGROUND: Endobronchial valve (EBV) placement for persistent air leaks (PAL) in active pulmonary infection remains controversial due to foreign body concerns. We compared EBV outcomes in infected patients against non-infectious controls. METHODS: We analyzed the National Inpatient Sample (2016-2023) for adults undergoing EBV placement for air leaks. Cohorts were stratified into non-infectious air leaks and complex pleuropulmonary infections. The primary outcome was clinical failure defined as mortality, surgical intervention, or new chest tube placement. RESULTS: Of 1,760 weighted patients, 52.6% had non-infectious leaks and 47.4% complex infections. Complex infection patients had longer length of stay (24.9 vs 16.0 days, p<0.001) and higher hospital costs ($93,817 vs $46,669, p<0.001). In multivariate analysis, infection was not an independent predictor of failure (p=0.994); however, mechanical ventilation (aOR 3.00; p<0.001) was associated with clinical failure in the adjusted model, and MRSA pneumonia (aOR 3.90; p=0.030) was associated with clinical failure in a separate pathogen-adjusted analysis. CONCLUSIONS: Among EBV-treated hospitalizations, Complex Infection was not significantly associated with composite clinical failure after adjustment, though device extraction rates were notably higher in this cohort. Mechanical ventilation was associated with clinical failure in the main adjusted model, and MRSA was associated with clinical failure in a separate pathogen-adjusted analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Endobronchial Valves for Persistent Air Leaks in Necrotizing Pneumonia and Complex Pleuropulmonary Infections: A National Analysis of Safety and Efficacy — Science Skim