Endobronchial Valves for Persistent Air Leaks in Necrotizing Pneumonia and Complex Pleuropulmonary Infections: A National Analysis of Safety and Efficacy.
Falah Abu Hassan, Yacoub Majdoubeh, Lisa Jarnagin, Raed Alalawi
Division of Pulmonary and Critical Care Medicine, The University of Arizona College of Medicine - Phoenix, Phoenix, Arizona, USA. Electronic address: falahiabuhassan@hotmail.com. · Department of General Surgery, Altnagelvin Hospital, Londonderry, Northern Ireland, United Kingdom.
Key points
From the paper's conclusion- Among EBV-treated hospitalizations, Complex Infection was not significantly associated with composite clinical failure after adjustment, though device extraction rates were notably higher in this cohort. Mechanical ventilation was associated with clinical failure in the main adjusted model, and MRSA was associated with clinical failure in a separate pathogen-adjusted analysis.
Abstract
BACKGROUND: Endobronchial valve (EBV) placement for persistent air leaks (PAL) in active pulmonary infection remains controversial due to foreign body concerns. We compared EBV outcomes in infected patients against non-infectious controls. METHODS: We analyzed the National Inpatient Sample (2016-2023) for adults undergoing EBV placement for air leaks. Cohorts were stratified into non-infectious air leaks and complex pleuropulmonary infections. The primary outcome was clinical failure defined as mortality, surgical intervention, or new chest tube placement. RESULTS: Of 1,760 weighted patients, 52.6% had non-infectious leaks and 47.4% complex infections. Complex infection patients had longer length of stay (24.9 vs 16.0 days, p<0.001) and higher hospital costs ($93,817 vs $46,669, p<0.001). In multivariate analysis, infection was not an independent predictor of failure (p=0.994); however, mechanical ventilation (aOR 3.00; p<0.001) was associated with clinical failure in the adjusted model, and MRSA pneumonia (aOR 3.90; p=0.030) was associated with clinical failure in a separate pathogen-adjusted analysis. CONCLUSIONS: Among EBV-treated hospitalizations, Complex Infection was not significantly associated with composite clinical failure after adjustment, though device extraction rates were notably higher in this cohort. Mechanical ventilation was associated with clinical failure in the main adjusted model, and MRSA was associated with clinical failure in a separate pathogen-adjusted analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endobronchial valves placement for persistent air leaks in critically ill patients: chest tube removal and competing risk of death.Frontiers in medicine · 2026
- Endobronchial valves for management of persistent air leak in advanced cystic fibrosis: A case report and review of literature.Respiratory medicine case reports · 2026
- Study Protocol of the Endobronchial VAlves for Pneumothorax to Reduce Admission Time (EVAPoRATe) Pilot Multicentre Randomised Clinical Trial.Respirology case reports · 2026
- Microbiological eradication of XDR Acinetobacter baumannii intra-abdominal infection using sulbactam-durobactam: clinical and microbiological outcomes amidst irreversible host comorbiditiesFrontiers in Medicine · 2026
- Personalized automatic management of tracheal cuff pressure and subglottic secretions drainage to prevent pneumonia in critically ill intubated patients. The MICROINHALO multicenter randomized controlled trialIntensive Care Medicine · 2026
- Analysis of pathogen distribution, clinical features and factors associated with lower respiratory tract multidrug-resistant organism isolation in patients with infectious pneumonia.Frontiers in medicine · 2026