Impaired lung function as an important risk factor for blood stream infections.
Magnus G Ahlström, Andreas Ronit, Børge G Nordestgaard, Susanne D Nielsen, Shoaib Afzal
Department of Clinical Microbiology, Copenhagen University Hospital - Amager and Hvidovre, Hvidovre, Denmark. · Department of Infectious Diseases, Copenhagen University Hospital - Amager and Hvidovre, Hvidovre, Denmark.
Key points
From the paper's conclusion- Impaired lung function is an important risk factor for blood stream infections and not limited to respiratory tract pathogens.
Abstract
BACKGROUND: The association of impaired lung function with blood stream infections has only been studied for a limited number of pathogens. We tested the hypothesis that impaired lung function is independently associated with higher risk of any blood stream infections and by specific pathogens in the general population. METHODS: Copenhagen General Population Study participants had spirometry performed at baseline and were followed for up to 10 years with linkage to the Danish Microbiology Database. The 10-year absolute risk, multivariable adjusted hazard ratio (HR), and population attributable fraction for blood stream infections were determined according to impaired lung function. Outcomes were any and pathogen-specific blood stream infections. RESULTS: In 118,565 participants, we identified 4160 blood stream infections among 3438 individuals during 950,718 person-years of follow-up. The HR was 1.5 (95% confidence interval (CI), 1.4-1.7) for individuals with obstructive spirometric pattern and 1.4 (95% confidence interval (CI), 1.2-1.5) for individuals with PRISm. The HR for blood stream infections were 1.4 (95% CI: 1.3-1.6) for forced expiratory volume 1-second (FEV1) 50-79% predicted and HR 2.5 (95% CI: 2.0-3.2) for FEV1 below 50% of predicted. A similar pattern was seen for all pathogen specific blood stream infections. The 10-year risk of blood stream infections was 5.4.3% (95% CI: 5.1-5.9) and 4.3% (95% CI: 3.9-4.7) for individuals with PRISm and obstructive spirometric pattern, respectively. The population-attributable fraction of blood stream infections attributable to abnormal spirometric pattern was 9.5% (95% CI: 6.4%-12.7%). CONCLUSION: Impaired lung function is an important risk factor for blood stream infections and not limited to respiratory tract pathogens.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between primary infection source and in-hospital mortality among adults with secondary bloodstream infection: a retrospective cohort study.Frontiers in cellular and infection microbiology · 2026
- Risk factors and clinical characteristics of bloodstream infection caused by ESBL-producing Klebsiella pneumoniae.Journal of infection in developing countries · 2026
- Association of preserved ratio impaired spirometry and restrictive spirometric pattern with incident atrial fibrillation: a cohort study.NPJ primary care respiratory medicine · 2026
- Clinical Characteristics and Predictors of Mortality in Elderly Patients with Bloodstream Infections: A 12-Year Retrospective Cohort Study.Clinical interventions in aging · 2026
- Bacterial profile, antimicrobial susceptibility patterns, and associated factors of lower respiratory tract infections among adult patients attending Nekemte Comprehensive Specialized Hospital: a cross-sectional studyBMC Infectious Diseases · 2026
- Incidence and factors associated with fusobacterium infection: prospective from a population-based cohort studyBMC Infectious Diseases · 2026