Key points
From the paper's conclusion- Knowledge-based BLS competency among the surveyed HCPs working in the participating hospitals remained suboptimal, with particularly notable knowledge gaps in defibrillation-related topics. Professional role, hospital level, and educational background were associated with knowledge-based BLS competency. These findings support the development of standardized, regular, and targeted CPR education, particularly for lower-level hospitals and professional groups with relatively lower knowledge-based BLS competency.
Abstract
BACKGROUND: High-quality cardiopulmonary resuscitation (CPR) is essential for improving outcomes after out-of-hospital cardiac arrest. The RITMICO study evaluated a newly developed double-click metronome, providing separate auditory cues for the compression and release phases, compared with a standard metronome. This secondary analysis investigated temporal changes in chest compression (CC) quality during prolonged manikin-based CPR simulations and explored factors associated with these trajectories. METHODS: 477 volunteers (54% male; mean age 34 ± 12 years) were included in the analysis. Compression depth, compression rate, and chest compression release velocity (CCRV) were recorded using an automated external defibrillator with CC quality analysis technology. Simulations were divided into 21 consecutive 5-s intervals, and median values for each metric were analyzed using linear mixed-effects models with subject-specific random effects. RESULTS: Compression depth and CCRV progressively declined over time, indicating early deterioration in CPR quality during prolonged compressions. Compared with the standard metronome, the double-click metronome produced consistently higher values for all CPR quality metrics throughout the simulation (all p < 0.05). It also delayed the decline of CCRV below the suggested threshold, indicating better preservation of chest recoil quality. Male participants maintained compression depth and CCRV longer than female participants. CONCLUSIONS: CPR quality deteriorated early during prolonged simulated chest compressions, particularly with respect to chest recoil. The use of a double-click metronome was associated with better preservation of CPR quality over time and a later deterioration in CCRV. These findings support a potential role for the double-click metronome in maintaining CPR quality during prolonged resuscitation, although confirmation in real-world clinical settings is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association of Chest Compression Depth, Rate, and Spring Resistance with "Quality CardioPulmonary Resuscitation" (QCPR) Scores in a Manikin Model.Journal of medical systems · 2026
- A structured progressive training intervention for chest compressions among primary health care personnel: a multicentre pilot non-randomised quasi-experimental study.BMC medical education · 2026
- Effects of deliberate practice at different training frequencies on long-term retention of high-quality chest compression proficiency among novice nurses: a quasi-experimental studyFrontiers in Medicine · 2026
- Computer Vision‐Guided Automated External Defibrillator System Improves Cardiopulmonary Resuscitation Accuracy: A Randomized Crossover TrialHealth Science Reports · 2026
- Cardiopulmonary resuscitation quality during the transition in care from paramedic services to emergency department teams.Prehospital emergency care · 2026
- Evaluation of Hemodynamic Data in an Ovine Model to Estimate Optimal Time for Compressor Change During Neonatal Resuscitation.Neonatology · 2026