Uncertainty-aware auto-segmentation enables adaptive radiotherapy planning of liver metastases.
Dominik Langner, Cihan Gani, Simon Boeke, Maximilian Niyazi, Carsten Eickhoff, Thomas Küstner, Daniela Thorwarth
Section for Biomedical Physics, Department of Radiation Oncology, University Hospital Tübingen, Tübingen, Germany. Electronic address: dominik.langner@med.uni-tuebingen.de. · Department of Radiation Oncology, University Hospital Tübingen, Tübingen, Germany.
Key points
From the paper's conclusion- The proposed pipeline seamlessly integrates accurate organ/lesion segmentation, interpretable uncertainty, and anatomy-guided post-processing to detect safety-critical segmentation failures and enable trustworthy AI auto-segmentation in clinical routine.
Abstract
PURPOSE: Despite remarkable auto-segmentation performance and growing clinical adoption, models frequently fail to generalize beyond the training distribution. Therefore, this study aimed to develop and validate an uncertainty-aware segmentation pipeline that yields high delineation accuracy for liver cancer patients and reliably identifies safety-critical segmentation imperfections in radiotherapy. MATERIALS AND METHODS: Datasets of n = 173 patients with 224 liver metastases were divided into training (n = 100), validation (n = 33), and test (n = 40). Each case included annotated T2-weighted magnetic resonance images. An nnU-Net segmented treatment-relevant organs and provided a margin-extended hepatic mask, which served as input to a second-stage SE-ResUNet for lesion delineation. Uncertainty was approximated via checkpoint ensembling under a cyclic learning-rate schedule, yielding entropy-based uncertainty maps and case-wise uncertainty scores. These guided an adaptive post-inference analysis consisting of (i) detection of potentially missed lesions and (ii) identification of problematic contours. Performance was evaluated on 40 patients (n = 52 lesions) using Dice Similarity Coefficient (DSC), 95%-Hausdorff-Distance (HD95), expected calibration error (ECE), uncertainty coverage, and the correlation between case-wise uncertainty scores and segmentation accuracy. RESULTS: Overall performance across treatment-relevant organs was DSC/HD95 = 0.89/4.8 mm; lesionsegmentation achieved DSC/HD95 = 0.86/4.9 mm. Uncertainty-guided post-processing, triggered in 14/40 cases, recovered 7 initially missed metastases, increasing lesion-level sensitivity from 84.6% (44/52) to 98.1% (51/52). Uncertainty estimates showed good calibration with ECE/uncertainty coverage for organs/lesion of 7.2/93.7% and 7.5/98.3%, and significant correlation between uncertainty/DSC (r = -0.802). CONCLUSION: The proposed pipeline seamlessly integrates accurate organ/lesion segmentation, interpretable uncertainty, and anatomy-guided post-processing to detect safety-critical segmentation failures and enable trustworthy AI auto-segmentation in clinical routine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving confidence in MRI-based auto-segmentation via uncertainty assessmentActa Oncologica · 2026
- Prior-refined Segment Anything Model enables quality-robust liver segmentation on cone-beam CT for adaptive radiotherapyScientific Reports · 2026
- Automated workflow for target volume propagation in online adaptive magnetic resonance guided radiotherapy for lung lesions using foundation models.Physics and imaging in radiation oncology · 2026
- Label-Free Threshold Selection for Out-of-Distribution Detection in Liver CT SegmentationmedRxiv · 2026
- Uncertainty as risk: A plug-and-play evidence-guided framework with error-aligned calibration for medical image segmentation.Medical image analysis · 2026
- Cross-fraction prior learning for scalable organ-at-risk segmentation in abdominal MR-guided radiotherapy.Medical physics · 2026