Radiography (London, England : 1995)

Ultra-portable chest X-ray in community tuberculosis screening: Operational lessons for radiologic technologists.

P Molee, P Awikunprasert, P Tavornshevin, N Wongboon, C Sangjam, P Tanwong

Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, 681 Samsen Road, Wachira Phayaban Subdistrict, Dusit District, Bangkok, 10300, Thailand. Electronic address: patamaporn.m@nmu.ac.th. · Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, 681 Samsen Road, Wachira Phayaban Subdistrict, Dusit District, Bangkok, 10300, Thailand. Electronic address: panatsada@nmu.ac.th.

Key points

From the paper's conclusion
  • Ultra-portable chest X-ray can support same-visit community TB screening and referral, but reliable implementation depends on the surrounding service system as well as the imaging device. The findings support practice considerations including early radiologic technologist input to site assessment, connectivity contingency planning, infection-prevention preparation, realistic workflow capacity, and workload support.

Abstract

INTRODUCTION: Ultra-portable chest X-ray can extend tuberculosis (TB) screening beyond hospital-based imaging services, but field implementation introduces operational constraints that are less visible in technical performance studies. This study examined practical lessons from a community-based TB screening programme, with emphasis on radiography practice. METHODS: A mixed-methods operational evaluation was conducted within a hospital-led active TB case-finding programme in high-risk urban communities in Bangkok, Thailand. Routine service records from all 22 ultra-portable X-ray-supported sessions were reviewed retrospectively. Research-specific data collected after ethics approval comprised service-recipient questionnaires (n = 140), staff questionnaires, and semi-structured interviews with 24 multidisciplinary staff. The Input-Process-Output framework was prespecified as the organising framework. Qualitative interview data were analysed descriptively using cumulative structured notes derived from review of the audio-recorded interviews. RESULTS: Across the 22 ultra-portable X-ray-supported sessions, 1161 chest X-ray examinations were performed, with a mean throughput of approximately 53 examinations per session. Abnormalities requiring referral were recorded in 162 examinations (14.0%), including 71 (6.1%) with findings suspicious for pulmonary TB and 91 (7.8%) with other abnormalities requiring clinical evaluation. Recurrent operational categories included site and environmental readiness, detector-workstation connectivity, equipment and image-acquisition constraints, radiation and infection safety, integrated review and referral workflow, multidisciplinary coordination, and workload and training requirements. CONCLUSION: Ultra-portable chest X-ray can support same-visit community TB screening and referral, but reliable implementation depends on the surrounding service system as well as the imaging device. The findings support practice considerations including early radiologic technologist input to site assessment, connectivity contingency planning, infection-prevention preparation, realistic workflow capacity, and workload support. IMPLICATIONS FOR PRACTICE: Community programmes using ultra-portable X-ray should consider radiologic technologists as contributors to pre-deployment planning, imaging safety, technical readiness, and workflow design, while prospectively monitoring image quality, repeat imaging, dose indicators, connectivity failures, and workload.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers