Abbreviated and full-protocol breast magnetic resonance imaging in the detection of breast cancer: A comparative diagnostic test accuracy meta-analysis.
A N Afandy, N O Afandy, H W Tan, Y X Tan, P Soh
Department of Radiology, Ng Teng Fong General Hospital, Singapore. Electronic address: ariel_novrianto_afandy@nuhs.edu.sg. · Department of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore.
Key points
From the paper's conclusion- abMRI demonstrates comparable specificity to fpMRI, with slightly lower sensitivity (approximately 2.61-4.78% difference) for breast cancer detection.
Abstract
INTRODUCTION: Abbreviated breast magnetic resonance imaging (abMRI) has emerged as a faster and potentially more accessible alternative to conventional full-protocol MRI (fpMRI). However, its diagnostic performance has been inconsistently reported across studies. This meta-analysis aimed to determine and compare the performance of abMRI and fpMRI for breast cancer detection. METHODS: CINAHL, EMBASE and PubMed were searched and finalised on 26 August 2026 for studies involving treatment-naïve women undergoing abMRI and/or fpMRI. Histopathology and/or clinico-radiological follow-up of ≥6 months served as the reference standard. Sensitivity and specificity were pooled using a bivariate random-effects model. Included studies were critically appraised with Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and -Comparative (QUADAS-C) tools. RESULTS: Seventeen studies comprising 5614 women were included. abMRI demonstrated a pooled per-patient sensitivity of 90.5% (95% confidence interval [CI]: 83.8-94.6%) and specificity of 75.4% (95% CI: 69.0-81.0%), with a pooled per-lesion sensitivity of 93.9% (95% CI: 86.7-97.3%) and specificity of 80.0% (95% CI: 71.0-86.4%). In comparison, fpMRI yielded a pooled per-patient sensitivity of 95.4% (95% CI: 92.1-97.4%) and specificity of 79.6% (95% CI: 70.2-86.6%), with a pooled per-lesion sensitivity of 96.3% (95% CI: 93.0-98.0%) and specificity of 80.0% (95% CI: 68.4-88.1%). Likelihood-ratio tests revealed significantly higher sensitivity for fpMRI than abMRI at per-patient level (p < 0.01). No significant differences in sensitivity was observed at per-lesion level and, specificity remained comparable between both protocols at per-patient and per-lesion levels (all p > 0.05). CONCLUSION: abMRI demonstrates comparable specificity to fpMRI, with slightly lower sensitivity (approximately 2.61-4.78% difference) for breast cancer detection. IMPLICATIONS FOR PRACTICE: abMRI may serve as a practical alternative to fpMRI in selected clinical settings where rapid imaging, improved accessibility and reduced resource utilisation are priorities, particularly when protocols incorporate T2 and/or diffusion-weighted imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Abbreviated MRI Protocols in Breast Cancer Diagnosis: A Narrative Review.Journal of clinical medicine · 2026
- Abbreviated versus full diagnostic protocol MRI for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis.European journal of radiology · 2026
- Abbreviated MRI protocol in breast cancer diagnosis: comparison with the full diagnostic protocol.Polish journal of radiology · 2026
- A systematic comparison of abbreviated and unenhanced breast MRI protocols in women with mammographically dense breasts compared to full multiparametric breast MR imagingEuropean Journal of Radiology · 2026
- Comparative performance of mammography, abbreviated-protocol breast magnetic resonance imaging (MRI), and full diagnostic protocol breast magnetic resonance imaging (MRI) in diagnosing early breast cancer.Clinical radiology · 2026
- Abbreviated MRI and Ultrafast MRI of the Breast.Journal of magnetic resonance imaging : JMRI · 2026