Impact of total suspended solids on disinfection efficacy of peracetic acid against Salmonella javiana.
Olabode O Akindolani, Mohsen Afshari, Tina Dong, Jamie A Hestekin
Ralph E. Martin Department of Chemical Engineering, University of Arkansas, 3202 Bell Engineering Center, Fayetteville, AR 72701, USA. · Department of Civil and Environmental Engineering, University of Houston, Houston, TX 77204, USA.
Key points
From the paper's conclusion- These findings have implications for water treatment facilities and highlight the significance of monitoring TSS levels to ensure effective disinfection using PAA.
Abstract
Peracetic acid (PAA) is frequently utilized in poultry processing as a microbial-control solution to reduce the presence of pathogens in poultry products. Although numerous studies have investigated the influence of acid concentration on microbial inactivation, only a limited number of studies have been documented regarding the effect of total suspended solids (TSS) on the potency of PAA against Salmonella. This study examines the impact of varying TSS concentrations (ranging from 40 to 500 mg/L) on the effectiveness of PAA in reducing Salmonella. At lower pH values (3.6, 6.0, and 7.0), PAA at 30 mg/L achieved complete disinfection of Salmonella in 60 seconds, while at higher pH values (8.0, 9.0, and 10.0), disinfection was faster, occurring within 30 seconds. PAA consumption varied by pH, with higher consumption at neutral and basic pH. Increasing TSS at a fixed pH of 9.5 reduced the antimicrobial efficacy of PAA, with higher TSS concentrations leading to less reduction in Salmonella compared to lower TSS levels over a 10-minute exposure. However, with longer contact times, antimicrobial efficacy improved. The study showed that complete elimination of Salmonella was achievable when TSS levels were less than 40 mg/L, and the disinfection process became significantly faster at TSS levels of 0 mg/L. It was suggested that this phenomenon might occur because the presence of solids could facilitate the accumulation of bacteria as a defense mechanism against disinfection, leading to the decreased efficacy of PAA. These showed that increase in TSS levels had negative effect on the effectiveness of PAA in eliminating Salmonella populations, providing insight into the influence of TSS on disinfection processes. These findings have implications for water treatment facilities and highlight the significance of monitoring TSS levels to ensure effective disinfection using PAA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of Peracetic Acid in Poultry Processing: Effects of Treatment Dynamics and Emerging Risk of Resistance Development in Salmonella spp.Comprehensive Reviews in Food Science and Food Safety · 2026
- Impacts on water quality before and after water line cleaning and disinfection with peracetic acid in swine farms.Translational animal science · 2026
- Valorization of Post-Coagulation Water Treatment Sludge via Microwave and Ultrasonic Disintegration: Evaluation of Leaching Behavior and Sustainable Reuse PotentialSustainability · 2026
- Inactivation of E. coli and P. aeruginosa by UV-A-Activated PMS and PDS, and Alkaline-Activated PDS: A Comparative StudyWater Air & Soil Pollution · 2026
- Performic acid disinfection in wastewater effluent and combined sewer overflows: A reviewWater Research · 2026
- Biofilm‐Mediated Persistence of Salmonella in Poultry Processing: A Comprehensive Review of Isolate Heterogeneity, Stress Adaptation, and Antimicrobial ResistanceComprehensive Reviews in Food Science and Food Safety · 2026