Practical radiation oncology

Global Interobserver Variation among Head and Neck Cancer Experts in Target Delineation and Plan Quality Given a Standardized Gross Tumor Volume.

Ugur Selek, Ahmed Nadeem Abbasi, Idil Bilgen, Salem Billan, Dukagjin M Blakaj, Sukran Celikarslan, Mustafa Cengiz, Bhisham Chera,

Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkiye. Electronic address: ugurselek@yahoo.com. · Department of Radiation Oncology, Aga Khan University Hospital, Karachi, Pakistan.

Computational

Key points

From the paper's conclusion
  • Even from a standardized GTV, experts did not achieve high agreement in target volumes or plans; disagreement widened in elective nodal coverage and OAR trade-offs. Consensus-based peer review, potentially with AI-assisted contouring and planning guidance, warrants prospective study to reduce interobserver variation and standardize plan optimization and acceptance.

Abstract

PURPOSE: To characterize divergence among international experts in clinical and planning target volume (CTV/PTV) delineation and resulting treatment plans when all begin from the same standardized gross tumor volume (GTV) and organs-at-risk (OAR) set, in two representative scenarios: HPV-associated oropharyngeal and EBV-associated nasopharyngeal carcinoma treated with definitive chemoradiotherapy. METHODS: A global panel recruited through ASTRO, ESTRO, IAEA, FARO, and regional radiation oncology societies received identical DICOM data for two anonymized cases, comprising an expert-defined GTV (primary GTVp, involved-node GTVn) and a shared OAR set; target delineation and planning were left to participants. Each expert drew CTV1/CTV2 (±CTV3) and PTV1/PTV2/PTV3 and produced a deliverable IMRT/VMAT plan. Contours pooled in ProKnow DS yielded a consensus atlas whose 50% iso-agreement envelope served as the consensus reference. Agreement was scored by matching, missing, and extra volume, Dice similarity coefficient (DSC), and mean center-of-mass (COM) displacement in X/Y/Z. Submitted plans were benchmarked against a consensus plan and published dose thresholds. RESULTS: Thirty-two experts contributed target delineations (per-structure N 26-32); 25 submitted complete, deliverable plans. CTV1 concordance was moderate-to-high but heterogeneous (oropharynx DSC 0.72 ± 0.19; nasopharynx 0.73 ± 0.19), approximating a GTV + ∼5 mm expansion, and fell for CTV2 (0.66 ± 0.17 and 0.67 ± 0.17). It was lowest for the elective low-dose nasopharyngeal PTV3 (0.45 ± 0.21; extra volume mean 245.5 cc, SD 310.5; COM shift up to ∼17-26 mm). Target coverage was adequate (oropharynx PTV1 D95 mean 69.4 Gy, SD 1.4; nasopharynx 68.7 Gy, SD 2.0). OAR doses, though generally within accepted limits, were heterogeneous: in nasopharynx, dispersion and the gap between the average expert and consensus plan were greatest for the optic apparatus, eyes/lens, cochleae, and brainstem, which the consensus plan spared substantially more than the population average; in oropharynx, dispersion was greatest for the supraglottic larynx, cochlea, brainstem, and spinal canal. CONCLUSIONS: Even from a standardized GTV, experts did not achieve high agreement in target volumes or plans; disagreement widened in elective nodal coverage and OAR trade-offs. Consensus-based peer review, potentially with AI-assisted contouring and planning guidance, warrants prospective study to reduce interobserver variation and standardize plan optimization and acceptance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers