◆ The Journal of prosthetic dentistry2026-09-24

Artificial intelligence system for identifying dental implants from intraoral radiographs: A diagnostic accuracy study.

Ana Cases-Sánchez, Eva González-Angulo, Alexandra Flesariu-Onu, Carla Fons-Badal, Lucía Fernández-Estevan

一句话结论 · In one sentence

The MovumStudio implant identification module demonstrated high diagnostic accuracy and reliability for recognizing most implant systems from periapical radiographs, offering a rapid, user-independent tool to support clinical decision-making.

原始摘要(英文原文)· Original abstract
STATEMENT OF PROBLEM: Identifying an implant system from radiographic images is essential for managing prosthetic complications but often relies on a clinician's subjective assessment and incomplete patient records. The increasing number of implant systems worldwide complicates accurate recognition and delays treatment procedures. PURPOSE: This study aimed to evaluate the diagnostic performance of a commercially available artificial intelligence software program in identifying different dental implant models from periapical radiographs. MATERIAL AND METHODS: An observational retrospective study was conducted using 720 anonymized periapical radiographs representing 12 implant systems. Each radiograph was uploaded into the MovumStudio implant identification module, and a response was considered correct when the software program identified the implant brand or model as the first option with ≥70% confidence. Descriptive and inferential statistics were performed to assess accuracy, sensitivity, specificity, predictive values, the Cohen kappa coefficient, and the area under the receiver operating characteristic curves (α=.05). RESULTS: The artificial intelligence system correctly identified 589 of 674 valid intraoral radiographs, achieving an overall accuracy of 87.4% (95% confidence interval, 84.9% to 89.9%) and a Cohen kappa value of 0.864, indicating almost perfect agreement. Sensitivity and specificity were ≥90% for most implant systems, with the area under the receiver operating characteristic curve above 0.90, except for the GMI Frontier system (area under the curve=0.55). The mean response time was 8.42 ±5.96 seconds. CONCLUSIONS: The MovumStudio implant identification module demonstrated high diagnostic accuracy and reliability for recognizing most implant systems from periapical radiographs, offering a rapid, user-independent tool to support clinical decision-making.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Artificial intelligence system for identifying dental implants from intraoral radiographs: A diagnostic accuracy study. — 科研速览 Science Skim