Separating oxygen transfer and contraction effects in placental BOLD MRI: volume-signal coupling in uncomplicated pregnancies and fetal growth restriction.
R Bartin, A Melbourne, F Gaudfernau, D Grevent, L Bussieres, L J Salomon
Department of Fetal Medicine, Surgery and Imaging, Hôpital Universitaire Necker Enfants Malades, AP-HP, Paris, France; Plateforme LUMIERE, Université Paris Cité, FETUS, F-75015, Paris, France. Electronic address: raphael.bartin@aphp.fr. · School of Biomedical Engineering & Imaging Sciences, Kings College London, London, United Kingdom.
Key points
From the paper's conclusion- This proof-of-concept framework enables assessment of oxygen transfer despite contractions and suggests contraction-signal coupling as a potential marker of placental structure and function.
Abstract
PURPOSE: Blood oxygen level-dependent (BOLD) MRI enables non-invasive assessment of placental function under maternal hyperoxia. Transient uterine contractions alter placental volume and BOLD signal, complicating the interpretation. Beyond this confounding effect, contraction-induced changes may reflect intrinsic placental biomechanical properties. OBJECTIVE: To separate contraction-from oxygenation-related BOLD components and investigate whether the volume-signal coupling could reflect of placental biomechanical integrity. METHODS: Among 125 pregnancies, 19 exhibited a single contraction during acquisition. Contractions were identified based on dynamic changes in placental shape, volume, and signal. Placental volume was modeled with an inverted gamma distribution, and the BOLD signal as the product of a sigmoid component (oxygenation response) and an inverted gamma term (contraction effect). We first validated the modeling framework using Bayesian fitting metrics. Contraction-related changes were then described using model-derived parameters. Finally, we derived a multivariate quadratic model describing volume-signal coupling in uncomplicated pregnancies and tested it fetal growth restriction (FGR) cases. RESULTS: The framework achieved robust fitting of both volume and BOLD signal dynamics. In uncomplicated pregnancies, contraction-related volume and signal responses were tightly coupled, with a consistent delay between volume and signal onset (median Δt = 54.5 s [33.6-79.4], p < 0.001) and significant amplitude differences (p = 0.016). FGR cases deviated systematically from the reference coupling and showed higher multivariate prediction errors (p = 0.003) suggesting altered mechanical-functional behavior. CONCLUSION: This proof-of-concept framework enables assessment of oxygen transfer despite contractions and suggests contraction-signal coupling as a potential marker of placental structure and function.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uteroplacental Responses to Physiological Challenges Throughout Pregnancy Using MRI.Journal of magnetic resonance imaging : JMRI · 2026
- T2* and susceptibility mapping as indicators of placental health.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026
- Advances in hypoxia-modulated blood oxygen level-dependent MRI: a narrative review of physiological principles and applications for glioblastoma imaging.Magma (New York, N.Y.) · 2026
- Voxel-wise temporal decomposition of hypoxia-powered BOLD MRI: method development and proof-of-concept application in glioblastomamedRxiv · 2026
- EP03.03 Hypoxia-stimulated BOLD MRI to differentiate tumor progression from treatment-related changes: Preliminary results of a prospective pilot studyNeuro-Oncology · 2026
- The ballon model revisited.Research square · 2026