Validation of automated script-based proton therapy optimisation for comparative head and neck planning.
Marte Kåstad Høiskar, Ulrik Vindelev Elstrøm, Peter Sandegaard Skyt, Kathrine Røe Redalen, Sigrun Saur Almberg
Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway. · Danish Centre for Particle Therapy, Aarhus University Hospital, Denmark.
Key points
From the paper's conclusion- The IMPT plan optimisation script created plans with comparable robustness, dose distribution, and NTCP to clinical plans and is applicable for selecting HNC patients for IMPT. Additionally, a standard field set-up was adequate for comparative planning for most patients.
Abstract
BACKGROUND AND PURPOSE: Proton and photon plan comparison is often the gateway to proton therapy for head and neck cancer (HNC). Manual planning is resource demanding, whereas automated planning may efficiently create consistent treatment plans. An automated rule-based intensity-modulated proton therapy (IMPT) plan optimisation script was developed within a commercial treatment planning system for comparative planning. This study benchmarked automated against clinical plans and evaluated whether a standard or patient-specific field set-up was necessary. MATERIALS AND METHODS: Twenty HNC patients previously treated with IMPT using manual plans were included. For each patient, two automated IMPT plans were generated, differing in field set-up: one with a standard five-field set-up and one matching the clinical field set-up. Robustness, dose distribution, and normal tissue complication probability (NTCP) for dysphagia and xerostomia were compared. RESULTS: On average, automated IMPT plans were created in 64 min. Compared with clinical plans, both automated plan types, generally, reduced organ of interest mean doses, with median differences of up to 3.3 Gy (glottis). Automated plans also had lower median NTCP for dysphagia of 0.1%-points (interquartile range (IQR): -0.8-0.9) and 0.3%-points (IQR: 0.0-0.6) for standard and clinical field set-ups, respectively. For xerostomia, the corresponding results were 0.3%-points (IQR: 0.0-1.5) and 0.3%-points (IQR: 0.1-0.8), respectively. CONCLUSIONS: The IMPT plan optimisation script created plans with comparable robustness, dose distribution, and NTCP to clinical plans and is applicable for selecting HNC patients for IMPT. Additionally, a standard field set-up was adequate for comparative planning for most patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated Radiotherapy Planning for Head-and-neck Cancer: Multi-institutional Development, Validation, and Clinical Implementation of Monaco Scripting.Journal of medical physics · 2026
- PROton therapy for HPV-related oroPHaryngeal cancer patients using normal tissue complication probability (NTCP) modEl-based strategy: an iTalian multIcenter retrospective Cross-sectional study - PROPHETIC.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Applying a pretrained DL-based IMPT planning workflow in an external center: A feasibility study in oropharyngeal cancer.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Real world clinical outcomes of deep learning based versus manual proton therapy planning for oropharyngeal cancer: A matched cohort study.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Nominal plan robustness may predict plan degradation in proton therapy for oropharyngeal head‐and‐neck cancerJournal of Applied Clinical Medical Physics · 2026
- Clinical implementation and evaluation of an artificial intelligence-driven one-click automatic planning system for functional lung avoidance radiotherapy.Practical radiation oncology · 2026