Intra-respiratory variation in tumour-diaphragm geometric association as a potential surrogate for dynamic tumour-tracking radiotherapy.
Takahiro Iwai, Masahiro Yoneyama, Noriko Kishi, Takanori Adachi, Mitsuhiro Nakamura, Yukine Shimizu, Hideaki Hirashima, Nobutaka Mukumoto,
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan. · Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
Abstract
Background and Purpose: For thoracic and upper abdominal tumours, respiratory motion management is essential; dynamic tumour-tracking radiotherapy (DTT-RT) is one such approach, but it typically requires fiducial marker (FM) insertion. We evaluated intra-respiratory variation in the tumour-diaphragm geometric association and its potential as a surrogate for DTT-RT. Materials and Methods: Data from 22 patients (11 lung cancer [LC]; 11 locally advanced pancreatic cancer [LAPC]), treated with FM-based DTT-RT, were analysed. Ten-phase, four-dimensional computed tomography was used to quantify the 3D gross tumour volume (GTV)-FM displacement, 3D GTV-diaphragm displacement, and 3D GTV centroid displacement under free-breathing (FB). Phase-wise relative displacements for GTV-FM, GTV-diaphragm, and the GTV centroid under FB were calculated along the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes as differences from the end-expiratory phase. Results: In LC, the mean 3D GTV-FM displacement, 3D GTV-diaphragm displacement, and 3D GTV centroid displacement under FB across all phases were 1.0 (range, 0-6.9), 4.6 (0.1-19.4), and 5.8 (0.1-31.8) mm, respectively (p < 0.001). In LAPC, corresponding values were 1.6 (0.2-4.7), 4.5 (0.3-21.8), and 3.2 (0.4-17.0) mm (p < 0.001). Phase-wise relative GTV-diaphragm displacement was largest in the SI direction in LC and in the AP direction in LAPC, with patterns primarily driven by inspiratory-phase variations. Conclusions: As a surrogate, the diaphragm exhibited larger intra-respiratory variation than FMs, primarily driven by inspiratory displacements. Incorporating phase-dependent tumour-diaphragm geometry may support markerless, diaphragm-based DTT for LC and LAPC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative assessment of respiratory-induced tumor motion using fluoroscopy and four-dimensional CT of solitary pulmonary lesions.Journal of applied clinical medical physics · 2026
- Within-patient four-dimensional computed tomography analysis reveals location-dependent motion of thoracic lymph nodes during respirationRadiation Oncology · 2026
- Geometric Motion of Multiple Liver Targets in Stereotactic Body Radiotherapy: Analysis of Translational and Rotational Motion with Different Motion-Management and Isocenter techniques.Biomedical physics & engineering express · 2026
- A real-time image-guided six-degree-of-freedom internal-external correlation framework for motion monitoring on a standard linear accelerator.Physics in medicine and biology · 2026
- Volume-based quantitative assessment of respiratory-induced organ motion in lung cancers.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Analysis of respiratory-induced tumor motion characteristics in different lung lobes using four-dimensional computed tomography images.Journal of cancer research and therapeutics · 2026