Development of an artificial intelligence driven dose prediction pipeline for online adaptive magnetic resonance-guided radiotherapy.
Benjamin Tengler, Moritz Schneider, Marcel Nachbar, Simon Boeke, Cihan Gani, Maximilian Niyazi, Paul Fischer, Christian F Baumgartner,
Section for Biomedical Physics. Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Germany. · Department of Radiation Oncology, University Hospital Tübingen, Germany.
Key points
From the paper's conclusion- The developed pipeline resulted in high-quality plans, ready for clinical use without further adjustments. AutoAdapt prioritized maximum rectum dose over D20% compared to manual planning, while requiring less manual work. In the future, AutoAdapt may be used to assist human planners and improve adaptive radiotherapy workflows.
Abstract
BACKGROUND AND PURPOSE: The closed-off nature of most treatment planning systems (TPS) limits the potential for using artificial intelligence (AI) tools during online adaptive treatments. The aim of this study was to develop an AI-driven pipeline (AutoAdapt) for online planning of adaptive radiotherapy usable in a closed-off setting, providing optimal plan constraints derived from a population-based dose prediction model. MATERIAL AND METHODS: The AutoAdapt pipeline consists of a physics-aware Swin UNet transformer network for dose prediction trained on 266 magnetic resonance images from 25 prostate cancer patients treated with 60 Gy on a 1.5 T magnetic resonance linear accelerator. The predicted dose was used to calculate plan constraints that were subsequently fed into a commercial TPS. AutoAdapt was tested using ten unseen cases and compared to manual plans based on clinical objectives, time, and complexity. RESULTS: While all plans were approved by a radiation oncologist, AutoAdapt met all clinical objectives in seven patients compared to ten when manually planned. AutoAdapt yielded a significantly lower D0.035cm3 to the rectum (p = 0.01). Manual plans achieved a median rectum V20Gy of 44% compared to 51% in AutoAdapt plans (p = 0.02). The pipeline only required a median of 29 s (7.5%) longer than the manual planners. CONCLUSIONS: The developed pipeline resulted in high-quality plans, ready for clinical use without further adjustments. AutoAdapt prioritized maximum rectum dose over D20% compared to manual planning, while requiring less manual work. In the future, AutoAdapt may be used to assist human planners and improve adaptive radiotherapy workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive Radiotherapy: Principles, Technologies, Clinical Applications, and Future Directions — A Comprehensive ReviewInternational Journal of Drug Delivery Technology · 2026
- Automated workflow for target volume propagation in online adaptive magnetic resonance guided radiotherapy for lung lesions using foundation models.Physics and imaging in radiation oncology · 2026
- Feasibility of DLAS-Driven Reoptimization to Accelerate MR-guided Online Adaptive Radiotherapy for Abdominal Malignancies.Practical radiation oncology · 2026
- Clinical indicators for dose re-optimization in magnetic resonance-guided online adaptive radiotherapy for prostate cancer.Physics and imaging in radiation oncology · 2026
- RadOncGym: An Agent-Based Framework for Radiotherapy Dose-Mimicking OptimizationarXiv · 2026
- Deep learning-enhanced image registration for accelerating daily adaptive magnetic resonance imaging-guided prostate radiotherapy.Physics and imaging in radiation oncology · 2026