Progress in cardiovascular diseases

Revisiting calcium plaque modification in contemporary times: Drill, shock, cut or none of the above?

Kevin Haddad, Anja Oksnes, Margaret McEntegart

Department of Medicine, New York-Presbyterian Hospital/Columbia University Irving Medical Center, United States of America. Electronic address: kh3397@cumc.columbia.edu. · Department of Medicine, New York-Presbyterian Hospital/Columbia University Irving Medical Center, United States of America.

Review

Key points

From the paper's conclusion
  • We propose a practical, imaging-guided algorithm, integrating randomized evidence and expert opinion, built on four questions: Can the lesion be crossed?

Abstract

Coronary artery calcification remains a major challenge in percutaneous coronary intervention (PCI), impairing lesion crossability and device delivery, increasing procedural complications, and predisposing to stent underexpansion, a key determinant of in-stent restenosis, stent thrombosis, and target-lesion failure. Because angiography detects only about half of coronary calcium, intravascular imaging has become central to identifying lesions that require advanced preparation and to confirming adequate modification before stent implantation. The contemporary toolbox includes devices with fundamentally different mechanisms of action: non-compliant, cutting, scoring, and super-high-pressure balloons; intravascular lithotripsy, with several novel platforms now emerging; rotational and orbital atherectomy; and excimer laser coronary atherectomy. Recent randomized trials have largely shown comparable imaging and procedural outcomes across strategies, and no device has demonstrated superiority for clinical endpoints. This review summarizes the mechanisms, technical considerations, indications, limitations, and comparative evidence for each technology. We propose a practical, imaging-guided algorithm, integrating randomized evidence and expert opinion, built on four questions: Can the lesion be crossed? What are the calcium severity and phenotype? Is the lesion adequately prepared for stenting? Is the stent adequately expanded? Device selection should be individualized according to calcium phenotype, patient and lesion characteristics, operator expertise, and cost, with non-compliant balloons remaining the cornerstone of initial lesion preparation. Ultimately, the goal is not maximal calcium modification but adequate lesion preparation and optimal stent expansion, with minimal procedural risk and cost.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers