Iwate Medical University Hospital/Department of Orthopaedic Surgery, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate 028-3695, Japan. Electronic address: 123aiko.1102@gmail.com. · Iwate Medical University Hospital/Department of Orthopaedic Surgery, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate 028-3695, Japan.
Key points
From the paper's conclusion- The contact area was greater for posterolateral plates (33%-44%) than for medial plates (14%-33%), indicating superior anatomical fit of the posterolateral plates. The mean angular bone parameters were 17.6 ± 4.0 °, 31.6 ± 4.0 °, and 52.0 ± 7.6 ° for LEA, MEA, and TA, respectively. In the ACU group, TA showed a significant negative correlation with the contact area of the medial plate, indicating that smaller TA values were associated with larger contact areas. Significant positive correlations between MEA and PBD were observed in the ACU and ZiBi groups, indicating that PBD increased as MEA increased. Regarding specific contact points, the ZiBi plates tended to contact the bone at the middle and distal portions, whereas the ACU and DeSy plates primarily contacted the proximal and distal portions.
Abstract
BACKGROUND: Distal humeral fractures in older patients with osteoporosis often present with complex anatomy and require robust initial fixation to allow early rehabilitation. We aimed to quantitatively evaluate the anatomical fit between the distal humerus and commercially available locking plates using three-dimensional (3D) modelling and to clarify the influence of bone morphology on the contact area between a plate and bone. HYPOTHESIS: Distal humeral morphology influences the contact area and anatomical conformity of locking plates. PATIENTS AND METHODS: Distal humeral specimens from 16 cadavers were used to evaluate plates from three manufacturers: Acumed (ACU), DePuy Synthes (DeSy), and Zimmer Biomet (ZiBi). 3D models of the bone and plates were reconstructed from CT data. The contact area was defined as the region where the distance between the plate and the bone was ≤0.1 mm. Skeletal parameters, including the lateral epicondylar angle (LEA), medial epicondylar angle (MEA), and tilting angle (TA), were measured. Statistical analysis was performed to identify correlations between these parameters, contact area and the plate-bone distance (PBD). RESULTS: The contact area was greater for posterolateral plates (33%-44%) than for medial plates (14%-33%), indicating superior anatomical fit of the posterolateral plates. The mean angular bone parameters were 17.6 ± 4.0 °, 31.6 ± 4.0 °, and 52.0 ± 7.6 ° for LEA, MEA, and TA, respectively. In the ACU group, TA showed a significant negative correlation with the contact area of the medial plate, indicating that smaller TA values were associated with larger contact areas. Significant positive correlations between MEA and PBD were observed in the ACU and ZiBi groups, indicating that PBD increased as MEA increased. Regarding specific contact points, the ZiBi plates tended to contact the bone at the middle and distal portions, whereas the ACU and DeSy plates primarily contacted the proximal and distal portions. DISCUSSION: The anatomical morphology of the distal humerus, particularly the TA and MEA, significantly affects the fit of locking plates. These findings provide valuable guidance for implant selection and preoperative planning to achieve optimal plate positioning in the treatment of distal humeral fractures. LEVEL OF EVIDENCE: Ⅳ; cadaveric study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Analysis of Fracture Line Distribution Using Three-Dimensional Mapping and Its Relationship to Plate Fixation in Intra-articular Distal Humerus Fractures: A Comparison of Young and Older Patients.The journal of hand surgery Asian-Pacific volume · 2026
- Designing an Anatomical Plate to Improve Biomechanics and Stability for Distal Humerus Fractures: FEM Investigation and the Influence of Meshing Strategy.The archives of bone and joint surgery · 2026
- Anatomical fit of a precontoured suprapectineal plate in japanese patients with acetabular fractures: A three-dimensional morphometric study.Injury · 2026
- Locked plate fixation versus non-operative management for three and four-part proximal humeral fractures in elderly; A randomized controlled trial.Injury · 2026
- A novel stiffness-distribution-controlled hybrid locking compression plate for osteoporotic midshaft clavicle fractures: a finite element study.BMC musculoskeletal disorders · 2026
- Radiographic Outcomes of Dorsal Bridge Plating Versus Volar Locking Plate Fixation for Distal Radius Fractures in Elderly Patients: A Single-Center Retrospective Study.Hand (New York, N.Y.) · 2026